Menus
15
to
17
Parameter
Parameter description
protocol
Performance
installed.
The
possible
categories
are
shown
below.
Refer
to
the
specific
Solutions
Module
User
Guide
for
more
information.
Parameters
common
to
all
categories
structure
Keypad
and
format
Advanced
parameter
descriptions
Serial
comms
5.16
Menus
15,
16
and
17:
Solutions
Module
slots
Pr
x.00
and
Pr
x.01
are
always
present
in
menus
15,
16
and
17.
Pr
x.01
indicates
which
type
of
module
is
present
(0
=
no
module
installed).
When
a
module
is
installed
the
drive
provides
the
relevant
menu
(menu
15
for
slot
1,
16
for
slot
2
and
17
for
slot
3)
depending
on
the
Solutions
Module
Most
modules
include
a
processor
and
parameters
are
updated
by
the
processor
in
the
Solutions
Module.
However,
dumb
modules
do
not
contain
a
processor
and
all
parameters
are
updated
by
the
drive
processor.
Dumb
Solutions
Module
parameters
are
read/written
by
the
drive
background
task
or
at
the
combined
update
time
for
time
critical
parameters.
The
combined
update
time
depends
on
the
number
and
type
of
dumb
Solutions
Modules
installed
to
the
drive.
For
each
Solutions
Module
the
update
rate
of
these
parameters
is
specified
as
4
ms,
8
ms,
etc.
The
combined
update
time
is
the
total
of
the
update
times
for
all
dumb
Solutions
Modules
installed.
For
example,
if
a
module
with
4
ms
update
time
and
a
module
with
8
ms
are
installed
to
the
drive,
then
the
combined
update
time
for
the
time
critical
parameters
of
each
module
is
12
ms.
In
the
parameter
tables
the
update
time
added
by
the
type
of
module
is
given,
for
example
4
ms
for
the
SM-Encoder
Plus
or
8
ms
for
the
SM-I/O
Plus.
When
parameters
are
saved
by
the
user
in
the
drive
EEPROM
the
option
code
of
the
currently
installed
module
is
saved
in
EEPROM.
If
the
drive
is
subsequently
powered-up
with
a
different
module
installed,
or
no
module
installed
where
a
module
was
previously
installed,
the
drive
gives
a
Slot.dF
trip.
The
menu
for
the
relevant
slot
appears
for
the
new
module
category
with
the
default
parameter
values
for
the
new
category.
The
new
parameters
values
are
not
stored
in
EEPROM
until
the
user
performs
a
parameter
save.
186
Mentor
MP
Advanced
User
Guide
www.onxcontrol.com
Issue
Number:
4
Solutions
Module
ID
Module
Category
0
No
module
installed
102
SM-Universal
Encoder
Plus
Feedback
104
SM-Encoder
Plus
and
SM-
Encoder
Output
Plus
201
SM-I/O
Plus
Automation
(I/O
Expansion)
203
SM-I/O
Timer
204
SM-I/O
PELV
205
SM-I/O24V
Protected
206
SM-I/O120V
207
SM-I/O
Lite
208
SM-I/O
32
304
SM-Applications
Plus
Automation
(Applications)
305
SM-Applications
Lite
V2
306
SM-Register
403
SM-PROFIBUS
DP-V1
Fieldbus
404
SM-INTERBUS
407
SM-DeviceNet
408
SM-CANopen
410
SM-Ethernet
421
SM-EtherCAT
Parameter
Range
Default
Type
x.01
Solutions
Module
ID
0
to
599
RO
Uni
PT
US
x.50
Solutions
Module
error
status
0
to
255
RO
Uni
NC
PT
Содержание Mentor MP
Страница 8: ...Menu 4 4 07 150 Mentor MP Advanced User Guide 7 Issue Number 4 www onxcontrol com ...
Страница 38: ...Mentor MP Advanced User Guide 35 Issue Number 4 www onxcontrol com ...
Страница 221: ......
Страница 222: ...0476 0002 04 ...