Parameter description
protocol
Performance
Menu
11
Gives
the
type/mode
of
the
data
block
selected
with
Pr
11.37
as
shown
below:
Gives
the
version
number
of
the
data
block.
This
is
intended
to
be
used
when
data
blocks
are
used
as
drive
macros.
If
a
version
number
is
to
be
Gives
the
checksum
of
the
data
block,
space
left
on
the
card,
the
total
space
on
the
card
for
the
card
flags
see
Pr
11.37
for
details.
Sets
the
timeout
for
the
drive
display
to
revert
to
status
mode
from
edit
mode
following
no
key
presses.
Although
this
parameter
can
be
set
to
less
Parameter
structure
Keypad
and
format
Advanced
parameter
descriptions
Serial
comms
stored
with
a
data
block
this
parameter
should
be
set
to
the
required
version
number
before
the
data
is
transferred.
Each
time
Pr
11.37
is
changed
by
the
user
the
drive
puts
the
version
number
of
the
currently
viewed
data
block
in
this
parameter.
than
2s,
the
minimum
timeout
is
2s.
Mentor
MP
Advanced
User
Guide
151
Issue
Number:
4
www.onxcontrol.com
Pr
11.38
String
Type/mode
0
FrEE
Value
when
Pr
11.37
=
0
1
3C.SE
Commander
SE
mode
parameter
file
(not
used)
2
3OpEn.LP
Open-loop
mode
parameter
file
3
3CL.VECt
Closed-loop
vector
mode
parameter
file
4
3SErVO
Servo
mode
parameter
file
5
3REGEn
Regen
mode
parameter
file
6
3DC
DC
mode
parameter
file
7-8
3Un
Unused
9
4C.SE
Commander
SE
mode
difference
from
default
file
(not
used)
10
4OpEn.LP
Open-loop
mode
difference
from
default
file
11
4CL.VECt
Closed-loop
vector
mode
difference
from
default
file
12
4SErVO
Servo
mode
difference
from
default
file
13
4REGEn
Regen
mode
difference
from
default
file
14
4DC
DC
mode
difference
from
default
file
15-16
4Un
Unused
17
LAddEr
Onboard
Application
Lite
user
program
file
18
Option
A
file
containing
user
defined
data
(normally
created
by
an
SM-
Applications
Solutions
Module)
19
OptPrg
A
file
containing
user
defined
data
(normally
created
by
an
SM-
Applications
Solutions
Module
user
program
(Digitax
ST
only)
11.39
SMARTCARD
data
version
Coding
Bit
SP
FI
DE
TE
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
Range
0
to
9,999
Default
0
Update
rate
Background
read/write
11.41
Status
mode
time-out
Coding
Bit
SP
FI
DE
TE
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
Range
0
to
250
s
Default
240
Update
rate
Background
read
11.40
SMARTCARD
data
checksum
Coding
Bit
SP
FI
DE
TE
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
Range
0
to
65,335
Update
rate
Background
write
Содержание Mentor MP
Страница 8: ...Menu 4 4 07 150 Mentor MP Advanced User Guide 7 Issue Number 4 www onxcontrol com ...
Страница 38: ...Mentor MP Advanced User Guide 35 Issue Number 4 www onxcontrol com ...
Страница 221: ......
Страница 222: ...0476 0002 04 ...