Parameter description
protocol
Performance
Menu
10
Table
5-9
Serial
communications
look-up
table
Trip
Categories
with
a
trip
with
a
lower
priority
number.
Unless
otherwise
stated,
trips
cannot
be
reset
until
1.0
s
after
the
trip
has
been
accepted
by
the
drive.
Parameter
structure
Keypad
and
format
Advanced
parameter
descriptions
Serial
comms
Trips
can
be
grouped
into
the
following
categories.
It
should
be
noted
that
a
trip
can
only
occur
when
the
drive
is
not
tripped
or
is
already
tripped
but
Mentor
MP
Advanced
User
Guide
139
Issue
Number:
4
www.onxcontrol.com
No.
String
No.
String
No.
String
1
UV
92
UP
ro
189
EnC1
2
t002
93
UP
So
190
EnC2
3
AOC
94
UP
ovr
191
EnC3
4
t004
95
UP
OFL
192-196
t192
-
t196
5
PS
96
UP
uSEr
197
EnC9
6
Et
97
UP
udf
198
EnC10
7
O.SPd
98
UP
ACC
199
dESt
8
PS.10V
99
t099
200
SL1.HF
9
PS.24V
100
201
SL1.tO
10
t010
101
t101
202
SL1.Er
11
tunE1
102-111
t102
-
t111
203
SL1.nF
12
tunE2
112-155
t112
-
t155
204
SL1.dF
13
tunE3
156
SLAVE.Er
205
SL2.HF
14
tunE4
157
F.OVL
206
SL2.tO
15
tunE5
158
AOP
207
SL2.Er
16
tunE6
159
FbL
208
SL2.nF
17
tunE7
160
Fbr
209
SL2.dF
18
tunE
161
AtL.Err
210
SL3.HF
19
t019
162-167
t162
-
t167
211
SL3.tO
20
It.AC
168
FdL
212
SL3.Er
21
O.ht1
169
FOC
213
SL3.nF
22
O.ht2
170
SL
214
SL3.dF
23
t023
171
S.OLd
215
SL.rtd
24
th
172
S.OV
216
t216
25
thS
173
th.Err
217-229
HF17
–
HF29
26
O.Ld1
174
PLL
Err
27
O.ht3
175
C.Prod
28
cL2
176
t176
29
cL3
177
C.Boot
30
SCL
178
C.BUSy
31
EEF
179
C.Chg
32-33
t032
-
t033
180
C.Optn
34
Pad
181
C.RdO
35
CL.bit
182
C.Err
36
SAVE.Er
183
C.dat
37
PSAVE.Er
184
C.FULL
38-39
t038
-
t039
185
C.Acc
40-89
t040
-
t089
186
C.rtg
90
UP
div0
187
C.Typ
91
UP
Par
188
C.cpr
Priority
Category
Trips
Comments
1
Hardware
faults
HF01
to
HF16
These
indicate
fatal
problems
and
cannot
be
reset.
The
drive
is
inactive
after
one
of
these
trips
and
the
display
shows
HFxx
2
Non-resetable
trips
HF17
to
HF29,
SL1.HF,
SL2.HF,
SL3.HF
Cannot
be
reset
3
EEF
trip
EEF
Cannot
be
reset
unless
a
code
to
load
defaults
is
first
entered
in
Pr
x.00
4
SMARTCARD
trips
C.Boot,
C.Busy,
C.Chg,
C.Optn,
C.RdO,
C.Err,
C.dat,
C.FULL,
C.Acc,
C.rtg,
C.Typ,
C.cpr
SMARTCARD
trips
have
priority
5
during
power
up
4
Encoder
power
supply
trips
Enc1,
Enc3
These
trips
can
only
override
the
following
priority
5
trips:
Enc2,
Enc9
or
Enc10
5
Normal
trips
All
other
trips
not
included
in
this
table
6
Self
resetting
trips
UV
Under
voltage
trip
cannot
be
reset
by
the
user,
but
is
automatically
reset
by
the
drive
when
the
supply
voltage
is
within
specification.
Trip
not
saved
to
EEProm