Menu
3
Parameter
Parameter description
protocol
Performance
The
terminations
may
be
enabled/disabled
by
this
parameter
as
follows:
Trips
can
be
enabled/disabled
using
Pr
3.40
as
follows:
Encoder
trips
+These
trips
can
be
enabled/disabled
by
Pr
3.40
encoder
types
either
directly
or
indirectly
as
listed
below.
Power
supply
short
circuit
or
overload
on
drive
encoder
terminals
structure
Keypad
and
format
Advanced
parameter
descriptions
Serial
comms
The
following
table
shows
trips
that
can
be
initiated
that
are
related
to
the
drive
encoder
feedback
and
whether
they
can
be
enabled
and
disabled
by
Pr
3.40.
1.
If
the
terminations
are
not
enabled
on
the
A,
B
or
Z
inputs
the
wire
break
system
will
not
operate
(5
V
or
8
V
only).
(Note
that
as
default
the
Z
input
terminations
are
disabled
to
disable
wire
break
detection
on
this
input.)
Wire-break
detection
It
may
be
important
to
detect
a
break
in
the
connections
between
the
drive
and
the
position
feedback
device.
This
feature
is
provided
for
most
There
is
an
overload
or
short
circuit
on
the
drive
encoder
terminals.
Power
supply
short
circuit
or
overload
on
option
encoder
supply
There
is
an
overload
or
short
circuit
on
the
option
encoder
power
supply.
Both
the
above
trips
can
over
ride
trip
Enc2
so
if
there
is
a
wire
break
trip
and
then
a
power
supply
trip
the
drive
will
store
both
trips
in
the
trip
log.
Both
the
above
trips
turn
the
terminal
encoder
supply
off.
52
Mentor
MP
Advanced
User
Guide
www.onxcontrol.com
Issue
Number:
4
3.39
{Fb08,
0.78}
Drive
encoder
termination
select
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
Range
0
to
2
Default
1
Update
rate
Background
read
3.40
Drive
encoder
error
detection
level
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
Range
0
to
2
Default
0
Update
rate
Background
read
Reason
for
error
Drive
trip
Power
supply
short
circuit
or
overload
on
drive
encoder
terminals
Enc1
(1)
+Hardware
wire-break
detect
on
A,
B
and
Z
inputs
Enc2
Power
supply
short
circuit
or
overload
on
option
encoder
supply
Enc3
Speed
feedback
selected
from
an
option
slot
that
does
not
have
a
position
feedback
category
Solutions
Module
installed
Enc9
Termination
Overload
Enc10
Bit
Function
0
Wire
break
detect
disabled
1
Wire
break
detect
on
A
and
B
(need
termination
enabled
for
5
V
and
8
V)
2
Wire
break
detect
on
A,
B
and
Z
(need
termination
enabled
for
5
V
signals)
Encoder
input
Pr
3.39=0
Pr
3.39=1
Pr
3.39=2
A-A\
Disabled
Enabled
Enabled
B-B\
Disabled
Enabled
Enabled
Z-Z\
Disabled
Disabled
Enabled
Device
Detection
method
Drive
Trip
Ab,
Fd,
Fr
Hardware
detectors
on
the
A(F),
B(D,R)
and
Z
signal
detect
a
wire
break
Enc2
Содержание Mentor MP
Страница 8: ...Menu 4 4 07 150 Mentor MP Advanced User Guide 7 Issue Number 4 www onxcontrol com ...
Страница 38: ...Mentor MP Advanced User Guide 35 Issue Number 4 www onxcontrol com ...
Страница 221: ......
Страница 222: ...0476 0002 04 ...