Parameter description
protocol
Performance
Menu
6
Setting
this
parameter
to
0
will
disable
the
drive.
It
must
be
at
1
for
the
drive
to
run.
When
this
parameter
is
set
up
correctly
for
the
local
currency,
Pr
6.26
will
give
an
instantaneous
read
out
of
running
cost.
If
this
parameter
is
one
the
energy
meter
(Pr
6.24
and
Pr
6.25)
is
reset
and
held
at
zero.
To
enable
the
feature
that
indicates
to
the
user
when
a
filter
change
is
due
Pr
6.18
should
be
set
to
the
time
between
filter
changes.
When
the
drive
is
running,
Pr
6.27
is
reduced
each
time
the
runtime
timer
hour
increments
(Pr
6.23)
until
Pr
6.27
reaches
0,
at
which
point
Pr
6.19
is
The
powered-up
clock
always
starts
at
zero
each
time
the
drive
is
powered-up.
The
user
can
change
the
time
from
the
keypad,
serial
comms
or
an
Parameter
structure
Keypad
and
format
Advanced
parameter
descriptions
Serial
comms
set
to
1
to
inform
the
user
that
a
filter
change
is
required.
When
the
user
has
changed
the
filter,
resetting
Pr
6.19
to
0
will
indicate
to
the
drive
that
the
change
has
been
done
and
Pr
6.27
will
be
reloaded
with
the
value
of
Pr
6.18.
Pr
6.27
can
be
updated
with
the
value
of
Pr
6.18
at
any
time
by
setting
and
clearing
this
parameter
manually.
application
module.
If
the
data
is
not
written
with
the
various
parts
in
the
correct
range
(i.e.
minutes
are
greater
than
59,
etc.)
the
clock
is
set
to
zero
on
the
next
minute.
This
clock
may
be
used
for
time
stamping
the
trip
log
if
Pr
6.28
=
0.
This
parameter
is
used
in
conjunction
with
Pr
6.21.
Mentor
MP
Advanced
User
Guide
101
Issue
Number:
4
www.onxcontrol.com
6.18
Time
between
filter
changes
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
Range
0
to
30,000
hrs
Default
0
Update
rate
Background
read
6.16
Electricity
cost
per
kWh
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
Range
0.0
to
600.0
currency
units
per
kWh
Default
0.0
Update
rate
Background
read
6.17
Reset
energy
meter
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
Default
0
Update
rate
Background
read
6.20
Powered-up
time:
years.days
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
3
1
1
1
1
1
Range
0
to
9.364
Years.Days
Update
rate
Background
write
6.15
Drive
enable
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
Default
1
Update
rate
4
ms
read
6.19
Filter
change
required
/
change
done
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
Default
0
Update
rate
Background
read/write
Содержание Mentor MP
Страница 8: ...Menu 4 4 07 150 Mentor MP Advanced User Guide 7 Issue Number 4 www onxcontrol com ...
Страница 38: ...Mentor MP Advanced User Guide 35 Issue Number 4 www onxcontrol com ...
Страница 221: ......
Страница 222: ...0476 0002 04 ...