62
MCi210 User Guide
Issue Number: 2
This parameter is used to perform a warm reset of the protocol interface. When set and the protocol
has reset, the parameter will be reset to zero (Off).
This parameter allows the protocol to be defaulted to factory settings. This includes all of the
protocol features, configuration, mappings and stored objects.
This parameter will indicate any Modbus configuration errors.
S.15.002
Reset
Minimum
0
Maximum
1
Default
0
Units
Type
1 Bit Volatile
Update Rate
Background read;
written to 0 on
initialization
Display Format
None
Decimal Places
0
Coding
RW
S.15.003
Default
Minimum
0
Maximum
1
Default
0
Units
Type
1 Bit Volatile
Update Rate
Read on module reset,
protocol interface reset
or protocol enable
Display Format
None
Decimal Places
0
Coding
RW
S.15.004
Modbus Configuration Error
Minimum
0
Maximum
2
Default
Units
Type
8 Bit Volatile
Update Rate
Write on module reset,
Modbus interface reset
or Modbus interface
enable
Display Format
None
Decimal Places
0
Coding
RO, Txt, ND, BU
Value
Text
Description
0
No error
No error
1
Port in use
Specified port is currently in use by another protocol
2
Timeout event
Timeout trigger event location is not valid
Содержание MCi210
Страница 1: ...User Guide Part Number 0478 0033 02 Issue 2 www controltechniques com MCi210 ...
Страница 78: ...0478 0033 02 ...