40
MCi210 User Guide
Issue Number: 2
This parameter shows the worst case free resource of the synchronous task.
This parameter displays the temperature, in Celsius, of the module’s PCB.
5.11
Menu 10 - Easy mode cyclic data
Menu 10 provides an easy method to configure up to 3 transmit and 3 receive cyclic links.
The minimum parameters required to configure a transmit link or a receive link are specified in
Table 5-3 and Table 5-4 below. In addition to these, each receive link can have its own timeout
configured with an additional custom action.
The Easy Mode Cyclic Data links can be synchronous links by configuring
All easy mode transmit links will transmit using the message rate set in
S.10.004
. For greater
control, advanced cyclic links can be used which allows individual link transmission rates.
Table 5-3 Transmit link parameters
Table 5-4 Receive link parameters
The Easy Mode Cyclic Data links can be made synchronous links by setting a value in
Tx Link
Maximum Network Delay
(
S.11.030
,
S.11.031
or
S.11.032
).
S.09.020
Synchronous Task Worst % Free
Minimum
0
Maximum
255
Default
Units
%
Type
8 Bit Volatile
Update Rate
Background write
Display Format
None
Decimal Places
0
Coding
RO, ND, NC, BU
S.09.030
PCB Temperature
Minimum
-128
Maximum
127
Default
Units
°
C
Type
8 Bit Volatile
Update Rate
Background write
Display Format
None
Decimal Places
0
Coding
RO, ND, NC
Transmit
Link
Profile
Link No
Source
Parameter
Parameter
Count
Type
IP
Address
1
S.10.010
S.10.011
S.10.012
S.10.013
S.10.014
S.10.015
2
S.10.020
S.10.022
S.10.022
S.10.023
S.10.024
S.10.025
3
S.10.030
S.10.033
S.10.032
S.10.033
S.10.034
S.10.035
Receive
Link
Profile
Link No
Destination
Parameter
Parameter
Count
Type
1
S.10.040
S.10.041
S.10.042
S.10.043
S.10.044
2
S.10.050
S.10.051
S.10.052
S.10.053
S.10.054
3
S.10.060
S.10.061
S.10.062
S.10.063
S.10.064
Содержание MCi210