50
MCi210 User Guide
Issue Number: 2
This parameter specifies the type of transmission for the receive link.
This parameter specifies the watchdog timer for the receive link. If no cyclic data is received on the
receive link the action taken will be determined by the setting in
Rx Timeout Action
(
S.10.046
,
S.10.056
or
S.10.066
).
S.10.044
Rx1 Link Source Type
S.10.054
Rx2 Link Source Type
S.10.064
Rx3 Link Source Type
Minimum
0
Maximum
4
Default
0 Units
Type
8 Bit User Save
Update Rate
Read on reset
Display Format
None
Decimal Places
0
Coding
RW, Txt, BU
Value
Text
Description
0
Direct
Link is Unicast or Broadcast
1
Multicast1
Link is multicast to the IP Address
2
Multicast2
Link is multicast to the IP Address
3
Multicast3
Link is multicast to the IP Address
4
Multicast4
Link is multicast to the IP Address
S.10.045
Rx1 Link Timeout
S.10.055
Rx2 Link Timeout
S.10.065
Rx3 Link Timeout
Minimum
0
Maximum
65535
Default
100
Units
ms
Type
16 Bit User Save
Update Rate
Read on reset
Display Format
None
Decimal Places
0
Coding
RW, BU
It is good system design to allow for some message loss by setting the timeout duration
to be greater than the transmit period by a factor of 2 or more.
NOTE