This parameter shows the Module firmware version in ww.xx.yy.zz format
This parameter shows the hardware version of the module.
The module serial number is available as a pair of 32 bit values where
Serial Number LS
(
S.00.004
)
provides the least significant 8 decimal digits and
Serial Number MS
(
S.00.005
) provides the most
significant 8 decimal digits. The reconstructed serial number is ((
S.00.005
x100000000) +
S.00.004
). For example serial number "0001234567898765" would be stored as
S.00.005
= 12345,
S.00.004
= 67898765.
S.00.002
Software Version
Minimum
0 (Display: 00.00.00.00)
Maximum
999999
(Display: 99.99.99.99)
Default
Units
Type
32 Bit Volatile
Update Rate
Power-up write
Display Format
Version Number
Decimal Places
0
Coding
RO, ND, NC, PT
S.00.003
Hardware Version
Minimum
0.00
Maximum
99.99
Default
Units
Type
16 Bit Volatile
Update Rate
Power-up write
Display Format
None
Decimal Places
2
Coding
RO, ND, NC, PT
S.00.004
Serial Number LS
Minimum
0
Maximum
99999999
Default
Units
Type
32 Bit Volatile
Update Rate
Power-up write
Display Format
None
Decimal Places
0
Coding
RO, ND, NC, PT
S.00.005
Serial Number MS
Minimum
0
Maximum
99999999
Default
Units
Type
32 Bit Volatile
Update Rate
Power-up write
Display Format
None
Decimal Places
0
Coding
RO, ND, NC, PT