MCi210 User Guide
33
Issue Number: 2
Safety
In
M
El
Pa
ra
V
D
Ti
Use
pr
Dia
gno
stics
Inde
x
This parameter displays the status of the module's Timer Unit. The following table details the status
word bits.
7 to 8
Timer Mode:
•
0 = Free Running Mode
The selected clock drives the counter. The Timer Event Flag (
(
S.03.002
) b0) is set on wraparound.
•
1 = Capture Mode 1
The selected clock drives the counter. A rising edge transition on Digital Input 3 causes
the current counter value to be latched into the Timer Capture Cache
(
S.03.005
)) parameter and the Timer Event Flag
Timer Unit Status Word
(
S.03.002
) b0) is set. The counter then continues incrementing
(the Timer Event Flag (
Timer Unit Status Word
(
S.03.002
) b0) is not set on wrap-around).
•
2 = Capture Mode 2
The selected clock drives the counter. A falling edge transition on Digital Input 3 causes
the current counter value to be latched into the Timer Capture Cache
(
S.03.005
)) parameter and the Timer Event Flag
Timer Unit Status Word
(
S.03.002
) b0) is set. The counter then continues incrementing
(the Timer Event Flag (
Timer Unit Status Word
(
S.03.002
) b0) is not set on wrap-around).
Note: Every time the Timer Event Flag is set an event task will be scheduled if is
configured (Bit 0-2).
In Free Running Mode (Mode 0) this will only occurs when timer counter wraps around.
In capture modes (Mode 1 and 2) this will only occurs when a rising or falling edge,
respectively, is detected.
9
External Source Clock selection:
•
0 = External clock provided on digital input 1 (
Digital Input 1 State
(
S.04.001
))
•
1 = External clock provided on digital input 2 (
Digital Input 2 State
(
S.04.002
))
S.03.002
Timer Unit Status Word
Minimum
0 (Display: 000)
Maximum
7 (Display: 111)
Default
Units
Type
8 Bit Volatile
Update Rate
Immediate
Display Format
Binary
Decimal Places
0
Coding
RO,ND,NC, BU
Bit Description
Содержание MCi210
Страница 1: ...User Guide Part Number 0478 0033 02 Issue 2 www controltechniques com MCi210 ...