58
MCi210 User Guide
Issue Number: 2
This enables the clock to provide time information using a single event message. If disabled the
clock will provide time information using the combination of an event message and a subsequent
general message.
This parameter selects the delay measurement. 0 = End-to-end; 1 = Peer-to-peer
End-to-end is the delay mechanism between slave clocks and the master clock.
Peer-to-peer delay mechanism provides not only the PTP event transit time information, but also
provides the corrections for the propagation delay of the link connected to the port receiving the
PTP event message.
This parameter controls the rate at which PTP Sync frames are sent. The message rate is
determined by raising 2 to the power of this parameter. E.g the default value of -2, results in four
sync messages per second.
S.11.014
1 Step Clock Correction
Minimum
0
Maximum
1
Default
1
Units
Type
1 Bit User Save
Update Rate
Read on reset
Display Format
None
Decimal Places
0
Coding
RW, Txt, BU
S.11.015
PTP Delay Measurement Select
Minimum
0
Maximum
1
Default
1
Units
Type
8 Bit User Save
Update Rate
Read on reset
Display Format
None
Decimal Places
0
Coding
RW, Txt, BU
Value
Text
Description
0
E2E Delay
End-to-end delay
1
P2P Delay
Peer-to-peer delay
S.11.016
PTP Sync Rate
Minimum
-4
Maximum
4
Default
-2
Units
Type
8 Bit User Save
Update Rate
Read on reset
Display Format
None
Decimal Places
0
Coding
RW
Содержание MCi210
Страница 1: ...User Guide Part Number 0478 0033 02 Issue 2 www controltechniques com MCi210 ...
Страница 78: ...0478 0033 02 ...