20
MCi210 User Guide
Issue Number: 2
This parameter specifies which User Customizable Image folder is currently selected and therefore
which user program is launched when the module is initialized. The currently selected folder is used
for any PC Tool downloads and may not be the same as the Active UCI Number.
This allows for multiple user programs / customizations to be stored in the option module. If the
selected UCI has been changed the module must be reset for the new application to become
active.
Please note the difference between the Selected UCI and the Active UCI (
Active UCI number
(
S.01.002
)). The Selected UCI is the image that the user wishes to be active after a module reset,
the Active UCI displays the UCI image currently active.
This parameter indicates the currently active UCI. All user program control and state parameters
and command relate to the Active UCI except for user program download via eCMP. This allows for
downloading to one UCI folder while running from another.
Note the difference between the Selected UCI (
Selected UCI number
(
S.01.001
)) and the Active
UCI. The Selected UCI is the image that the user wishes to be active after a module reset, the
Active UCI displays the UCI image currently active.
This parameter indicates the status of a user program, if it is present. If no user program is present
in the module then it will also indicate this.
If the status indicates a run-time error (3, Error) the user's Error task may be running otherwise the
user program will have stopped.
S.01.001
Selected UCI number
Minimum
0
Maximum
9
Default
0
Units
Type
8 Bit Volatile
Update Rate
Read during
initialization
Display Format
None
Decimal Places
0
Coding
RW, ND, NC, PT, BU
S.01.002
Active UCI number
Minimum
0
Maximum
9
Default
Units
Type
8 Bit Volatile
Update Rate
Background write
Display Format
None
Decimal Places
0
Coding
RO, ND, NC, PT, BU
S.01.003
User Program Status
Minimum
0
Maximum
3
Default
Units
Type
8 Bit Volatile
Update Rate
Background write
Display Format
None
Decimal Places
0
Coding
RO, Txt, ND, PT, BU