44
MCi210 User Guide
Issue Number: 2
This parameter is used to enable the easy mode cyclic Data. If set to zero, the transmit and receive
cyclic links will be disabled even if all the setup parameter are correctly configured.
This parameter is used to perform a warm reset of the easy mode cyclic data interface. This
parameter will be automatically set to Off (0) when the reset has been completed.
This parameter must be set after any changes are made to the parameters in menu 10 to ensure
that the changes take effect.
Setting this parameter will only effect menu 10 and does not affect the other menus or protocols
supported by the module.
This parameter allows all parameters in menu 10 to be defaulted to factory settings.
To default the parameters in menu 10, set this parameter to On (1) and then reset the menu by
setting Reset (
S.10.002
) to On (1), or reset the module by setting Reset Module (
S.00.007
) to On
(1). This parameter will be automatically set to Off (0) when the default operation has been
completed.
S.10.001
Enable
Minimum
0
Maximum
1
Default
1
Units
Type
1 Bit User Save
Update Rate
Background read
Display Format
None
Decimal Places
0
Coding
RW, BU
S.10.002
Reset
Minimum
0
Maximum
1
Default
0
Units
Type
1 Bit Volatile
Update Rate
Background read
Display Format
None
Decimal Places
0
Coding
RW
S.10.003
Default
Minimum
0
Maximum
1
Default
0
Units
Type
1 Bit Volatile
Update Rate
Read on reset
Display Format
None
Decimal Places
0
Coding
RW