Appendix 2 Circuit Diagram 101
Appendix 2 Circuit Diagram
BR
BK
GY
BR
BK
GY
BR
BK
GY
BR
BK
GY
BR
BK
GY
TO P53 ON CHILLED WATER UNIT.
16. EC FAN CONNECTION, TO TERMINAL P51 ON DX/DUAL COOL/FREE COOL UNIT,
SEE NOTE 16
SEE NOTE 16
BR
BL
BL
BR
BR
BL
(KL3)
(KL3)
(KL3)
7
3
7
3
7
3
ECF3
8
2
ECF2
8
2
ECF1
8
2
ACT2
CWCV
GN
W
BK
GY
OPTIONAL
LPT2
GN
W
BK
GY
OPTIONAL
LPT1
GN
W
BK
GY
OPTIONAL
HPT2
ACT1
CWCV
W
BR
BL
1
3
2
BL
BR
BR
BL
BL
BR
(KL3)
(KL3)
(KL3)
7
3
7
3
7
3
ECF3
8
2
ECF2
8
2
ECF1
8
2
BR
ACT1
ECOCV
OL2
OL1
OL3
SEE NOTE 4
OL1,2,3
A
B
C
D
A
B
C
65
65
8
7
6
5
4
3
2
1
D
60
55
50
45
40
35
30
25
20
15
10
5
5
10
15
20
25
30
35
40
45
50
55
60
8
7
6
5
4
3
2
1
BK
R
R
R
R
BR
BR
BR
W
W
BR
BL
BL
BL
BL
BL
BR
R
R
CP
SDT
4
3
2
1
SDC
RESET
5
50 24 90
G5
93
92
91
R
R
R
93
92
91
SD
1
5
6
R
BK
R
R
R
R
2
3
R
SEE NOTE 12
ALTERNATE P65 CONNECTION
FACTORY MOUNTED MAIN UNIT SWITCH
SEPERATE CB FOR REHEAT 2
FOR 2 BAY & 3 BAY UNITS
FAN MOTOR OVERLOAD
AS
GCD
Q4
Q3
Q2
Q1
RCP1
RC1
1P
2
3
1
BL
BR
W
DLT1
WUF
HPT1
12-8
12-6
12-7
12-5
OPTIONAL
12-4
12-2
12-3
12-1
GY
BK
W
GN
61,62,63
15,19,
RCP2
L3
L2
L1
26
25
15
18
OPTIONAL PHASE FAULT RELAY
TO 51
TO 24
TO 37B
TO 38B
OPTIONAL 1 PHASE REMOTE CONDENSER 1, 2
RC2
1P
CCH2
4C2
CCH1
OPTIONAL 3 PHASE REMOTE CONDENSER 1, 2
3P RC1,2
4C1
R 2BR
OFF ON
10
9
8
7
6
5
4
3
2
(SEENOTE15)
IRHUMIDIFIERSETTING
SWB2
1
G5
G2
G3
G4
(EM1)
WIRE ID MARKINGS TAKE PRECEDENCE
FOR GUIDANCE ONLY
WIRING COLOUR CODES ARE
ATTENTION
BK
BK
R
R
R
R
R
R
BR
R
R
53-3
53-2
1
SEE NOTE 11
5C1
5C2
15,20,61,62,63
15,61,62,63
R
EC FAN OPTION
(KL2)
(KL2)
ECF2,3
ECF1
HS3
GN/Y
BR
1CPAR
MF3
T3
T4
T2
T5
2
PHECV
ACT2
3
2
BL
BR
W
PHECV
ACT1
3
1
Q17
Q18
22-6
22-3
22-1
R3 IS PRESENT
REMOVE WIRES WHEN
BL
BR
W
LINE
OPTIONAL DEVICES
37
40
27
28
28
13
54,62
18
24
17
23
58
50
13
65
65
34
14
48
20
26
5
RS4,5,6 - REHEAT 2 SAFETY STATS
RH2 - REHEAT STAGE 2 CONTACTOR
ELECTRIC REHEAT 2
SDT - SMOKE DETECTOR TROUBLE RELAY
SDC - SMOKE DETECTOR CONTROL
SD - SMOKE DETECTOR
OTHERS (75VA MIN RATING)
RSD - REMOTE SHUTDOWN DEVICE BY
RCP - REMOTE CONDENSER POWER
(75VA MIN. RATING)
RAD1 - 4 REMOTE ALARM DEVICE
CONTACT LOAD
R3 - EXTRA COMMON ALARM 24V, 3.0A MAX
MFAS - MAIN FAN AUXILIARY SIDE SWITCH
LQR - LIQUITECT SHUTDOWN RELAY
LPT2 - LOW PRESSURE TRANSDUCER 2
LPT1 - LOW PRESSURE TRANSDUCER 1
HTS - HIGH TEMPERATURE STAT
HPT2 - HIGH PRESSURE TRANSDUCER 2
HPT1 - HIGH PRESSURE TRANSDUCER 1
GCD - GROUND CURRENT DETECTOR
RELAY (DEFAULT RAD1)
EM1 - EMERGENCY POWER LOCKOUT
(GROUND CURRENT DETECTOR)
CT - CURRENT TRANSFORMER
SWITCH
CPSS - CONDENSATE PUMP SAFETY
CPAR - CONDENSATE PUMP ALARM RELAY
CP - CONDENSATE PUMP
" FOR INFRA RED HUMIDIFIER.
OFF
2, 4, 5, 6, 7, 9 & 10 ARE IN THE "
" POSITIONANDSWITCHES
ON
15. CONTROL BOARD DIP SWITCH(SW2), ENSURE THAT 1 & 3 ARE IN "
14. "WARNING" LEVEL ALARM CONNECTION.
13. REMOTE CONDENSER POWER CONTACTOR OPTIONAL FOR AIR COOLED SYSTEMS
AT SCREW TERMINALS 77 AND 78.
12. ON UNITS WITH NO INTELLISLOT, CONNECT PLUGS 65-1 AND 65-2 TO ALTERNATE CONNECTIONS
DIRECTLY FROM OL1,2,3.
WITHIN EC FAN. OL1,2,3 USED WITH EC OPTION, MF1
¡ ¢
MF2 & MF3 ARE CONTACTORS DRIVEN
11. 5MF CONTACTS NOT USED WITH EC FAN OPTION FOR MAIN FAN OVERLOAD. USE KL2 CONTACT
FOR REMOTE INDICATION.
10. OPTIONAL CONDENSATE PUMP ALARM RELAY TERMINALS LOCATED IN WIRING COMPARTMENT
PROVIDED FOR REMOTE 24V AC SOURCE.
9. OPTIONAL EMERGENCY POWER LOCKOUT OF REHEAT AND/OR HUMIDIFIER: CONNECTIONS
COMPARTMENT FOR REMOTE INDICATION. FIELD TO CONNECT 24V MAX.
8. OPTIONAL MAIN FAN AUXILIARY SIDE SWITCH: TERMINALS LOCATED IN FIELD WIRING
REMOTE INDICATION. FIELD TO CONNECT 24V MAX.
7. OPTIONAL SMOKE DETECTOR: TERMINALS SUPPLIED IN FIELD WIRING COMPARTMENT FOR
6. JUMPER TO BE REMOVED WHEN OPTIONAL COMPONENT IS USED.
5. THREE PHASE MOTORS PROTECTED FOR PRIMARY SINGLE PHASING CONDITION.
SHOWN IN BOXED AREA.
VOLTAGE OVERLOAD SYSTEM SHOWN IN SHADED AREAS, LINE VOLTAGE OVERLOAD SYSTEM
4. FAN MOTOR OVERLOAD SYSTEM DEPENDENT ON FAN MOTOR MANUFACTURER, CONTROL
3. (BLANK).
2. SEE INSTALLATION AND USER MANUAL(S).
1. ALL FIELD WIRING TO BE PER LOCAL CODES. USE COPPER CONDUCTORS ONLY.
NOMENCLATURE
STANDARD DEVICES
STANDARD DEVICES
LINE
LINE
NOTES:
9
30
43
16
43
38
34
37
32
56
49
34
39
37
14
44
13
42
25
9
3
2
27
28
46
60
56
55
52
48
47
13
14
42
41
40
39
18,20
50
58
47
55
7
2
50
58
56
14
52
49
41
30
29
52
60
38
FTS - FLUID TEMPERATURE SENSOR
WATER CONTROL VALVE
ACT1ECOCV - ACTUATOR 1 ECOIL
DUAL COOL/FREE COOL
KL3 - EC FAN TERMINALS
KL2 - EC FAN ALARM TERMINALS
ECF - EC FAN
EC FAN
EXCHANGER CONTROL VALVE
ACT2PHECV - ACTUATOR 2 PLATE HEAT
EXCHANGER CONTROL VALVE
ACT1PHECV - ACTUATOR 1 PLATE HEAT
GLYCOL/WATER COOLED
WATER CONTROL VALVE
ACT2CWCV - ACTUATOR 2 CHILLED
WATER CONTROL VALVE
ACT1CWCV - ACTUATOR 1 CHILLED
CHILLED WATER
DSV2 - DIGITAL SCROLL SOLENOID VALVE 2
DSV1 - DIGITAL SCROLL SOLENOID VALVE 1
DITITAL SCROLL
RS1,2,3 - REHEAT 1 SAFETY STATS
RH1 - REHEAT STAGE 1 CONTACTOR
BR - BACKUP REHEAT RELAY
ELECTRIC REHEAT 1
HWA - HIGH WATER ALARM
(UNDER PAN)
HS3 - MANUAL RESET HUMIDIFIER SAFETY
HMV - HUMIDIFIER MAKE-UP VALVE
H - HUMIDIFIER CONTACTOR
INFRARED HUMIDIFIER
WUF - WATER UNDER FLOOR
U1-U30 - OPTO ISOLATORS
T6 - ISOLATION TRANSFORMER
T1 - UNIT CONTROL TRANSFORMER
TH - TEMPERATURE SENSOR
Q18 - NOT USED
Q17 - NOT USED
Q15 - NOT USED
Q14 - COMPRESSOR NO.1 TRIAC
TRIAC
HOT GAS BYPASS 1
Q13 -
Q12 - LIQUID LINE SOLENOID NO.1 TRIAC
Q10 - COMPRESSOR NO.2 TRIAC
Q9 - HOT GAS BYPASS 2 TRIAC
Q8 - LIQUID LINE SOLENOID NO.2 TRIAC
Q6 - HUMIDIFIER MAKE-UP TRIAC
Q5 - MAIN FAN TRIAC
Q4 - HUMIDIFICATION TRIAC
DE HUMIDIFICATION VALVE
Q3 -
Q2 - REHEAT STAGE 2 TRIAC
Q1 - REHEAT STAGE 1 TRIAC
MF - MAIN FAN CONTACTOR
LP2 - LOW PRESSURE SWITCH NO. 2
LP1 - LOW PRESSURE SWITCH NO. 1
LLSV2 - LIQUID LINE SOLENOID 2
LLSV1 - LIQUID LINE SOLENOID 1
MAX CONTACT LOAD
K3 - COMMON ALARM RELAY 24V, 1.0A
HU - HUMIDITY SENSOR
HP2 - HIGH PRESSURE SWITCH NO.2
HP1 - HIGH PRESSURE SWITCH NO.1
(SINGLE COMP. MODEL ONLY)
HGBP1 - HOT GAS BYPASS
FC - FILTER CLOG SWITCH
DLT2 - DISCHARGE LINE THERMOSTAT 2
DLT1 - DISCHARGE LINE THERMOSTAT 1
DHV - DEHUM VALVE
CCH2 - CRANKCASE HEATER NO.2
CCH1 - CRANKCASE HEATER NO.1
C2 - COMPRESSOR CONTACTOR 2
C1 - COMPRESSOR CONTACTOR 1
AS - AIR SAFETY SWITCH
19
SDT
BR
BL
7-1
7-2
FTS
CONNECTION
DEVICE
REJECTION
HEAT
71A
70A
71
70
C2
R
R
C1
R
R
EM1
7
NOTE
SEE
10
NOTE
SEE
80
81
88
89
84
85
77
78
82
83
59
58
75
76
94
95
96
97
SYSTEM
MONITORING
TO
W/OR
OR
65-2
65-1
R
R
8
NOTE
SEE
ALL FIELD WIRING - SEE NOTE 1
"
OPTIONAL
"
INDICATOR
LIQUITECT
REMOTE
CONNECTION
ALARM
COMMON
2LQR
P
P
1R3
R
R
2R3
R
R
3R3
BR
BR
BR
BR
2CPAR
P
P
MFAS
P
P
P
P
9
NOTE
SEE
EARTH
NEUTRAL
CONNECTION
EARTH GROUND
OPTIONAL
OPTIONAL
MF3 ON 3 BAY UNITS
MF2 ON 2 BAY UNITS
MF1 ON 1 BAY UNITS
PHASE FAULT RELAY CONNECTS TO
RCP1
5MF2,3
5MF1
RCP2
CUSTOMER CONNECTIONS, ALSO SEE LINES 2,3,5,6,13,18,19,20,22,28 & 29
3MF1,2,3
2MF1,2,3
1MF1,2,3
MF1
29,35
30
24,39
OPTIONAL WITH GCD
54-5
53-5
54-3
54-2
13-6
13-5
R
R
43
44
13-2
13-1
R
R
41
42
SEE NOTE 6
RS6
RS5
RS4
FOR 1 BAY UNITS
REHEAT 2 USES CB1 OF REHEAT 1
CBRH2 NOT FITTED
OPTIONAL REHEAT 2
R
BR
L3
L2
L1
CT
1
2
R
R
R
1BR
LP1
BR
HP1
33-6
BL
U27
LP2
BR
HP2
33-7
U24
65-4
65-1
61-8
61-1
K3
GN/Y
E-1
12-6
12-5
R
BK
43
44
12-2
12-1
67-6
67-1
R
BK
41
42
45-3
SHADEDAREASMAYBEFUSES
12
45,62
8,25,33,42,43,
10,27,46,47,49,54
38,39,41
52,53,54
55,57,58
24,39
19,23
15,18,20 12,23
24,24
24-2
(
)
SEE NOTE 6
R
(
)
ORCIRCUITBREAKERS
R
R
INCLUDED WITH R3
L3 L2 L1
ELECTRICAL REHEAT
LLSV1
L3
L2
L1
MAIN FAN 1,2,3
1RH1
L3
L2
L1
3RH2
2RH2
1RH2
3RH1
2RH1
(OPTIONAL)
REHEAT2
REHEAT 1
COMPRESSOR NO.2
L3
L2
L1
3C2
2C2
1C2
33-3
32-12
32-7
11-8
11-6
11-7
11-5
33-8
33-9
32-13
32-5
36-10
33-5
33-4
32-3
36-9
R
R
C2
Q10
BL
U25
U26
LLSV2
BL
BR
BR
Q9
Q8
Q15
R
32-10
32-6
11-4
11-2
11-3
11-1
32-8
32-9
32-11
32-4
33-2
32-2
33-1
32-1
R
R
C1
Q14
BL
U28
U29
HGBP1/DSV1
BL
BR
BR
Q13
Q12
HGBP2/DSV2
51-5
51-3
51-2
51-1
35-7
35-6
35-2
BR
35-1
34-8
34-6
34-4
36-4
34-11
34-9
34-5
34-7
51-4
35-5
34-10
34-2
34-1
34-3
36-7
36-5
BL
R
BL
R
R
R
BR
R
R
H
DHV
RH2
RH1
R
R
U15
R
R
24G
24H
R
34-12
R
24DG
24DH
BR
RS3
RS2
RS1
R
R
54-4
53-4
52-5
54-1
53-1
52-3
52-2
52-1
52-4
22-4
22-2
22-5
OR
8-1
8-2
8-3
8-4
36-14
36-13
36-15
8-7
39-1
40-12
40-1
8-6
36-8
BR
BR
1LQR
36-3
40-13
36-6
40-11
36-2
40-10
35-4
36-1
40-9
35-3
39-4
R
39-3
8-5
39-2
40-5
40-3
R
R
4-4
4-3
4-2
4-1
45-1
45-2
4-4
4-3
4-2
4-1
43-2
41-2
41-1
43-1
E2
E4
E5
E3
24-1
E1
64-8
64-1
66-6
66-1
R
1 & 7
NOTES
SEE
OR
P
OR
SEE NOTE 6
PCB CONTROL FUSES
24V
T1
T6
FC
HMV
R
R
24
CPSS
P
R
BR
38-2
40-8
U19
U18
U17
U16
56
55
51
50
RAD2
RAD1
R
P
P
R
R
R
R
40-7
40-6
40-4
40-2
38-3
LQR
CPAR
K3
K3
R3
SEE NOTE 6
R
U22
BR
R
R
MF2
U21
R
R
BR
BL
Q5
Q6
U23
SEE NOTE 6
REMOVE FOR EXTRA RSD TERMINALS
R
R
R
38
37
38B
37B
38C
37C
RSD1
RSD2
RSD3
U20
HWA
HTS
R
BR
BL
BR
BL
COMPRESSOR NO.1
L3
L2
L1
L3
L2
L1
3C1
2C1
1C1
3H1
2H1
1H1
GY
BK
BR
SAFETIES
BREAK
WITH LINE
HUMIDIFIER
INFRARED
BK
BK
L3
L2
BK
L1
CONNECTION
EARTH GROUND
GN/Y
WIRE SIZING
FOR MAIN SUPPLY
SEE UNIT NAMEPLATE
SUPPLY
3 PHASE
VOLTAGE
LINE
45-4
41-4
41-3
R
R
R
R
R
R
OR
OR
R
INFRAREDHUMIDIFIER50Hz
WIRINGDIAGRAM
Q
GROUND CURRENT DETECTOR CIRCUIT
TRIAC GATE CONNECTION
CIRCUIT CONNECTION TO ELECTRONICS
TERMINAL STRIP CONNECTION FOR FIELD WIRING
TERMINAL BLOCK CONNECTION ON CONTROL BOARD
PLUG CONNECTION ON FUSE BOARD
PLUG CONNECTION ON CONTROL BOARD
OPEN CONTROL BOARD CONNECTION
INLINE QUICK DISCONNECT
ELECTRONIC SWITCH (TRIAC) Q1-Q18
WIRING AND DEVICES INCLUDED IN OPTIONS
CONTROL BOARD INTERNAL WIRING - 24 VOLT MAX
FIELD SUPPLIED 24 VOLT WIRING
FACTORY SUPPLIED 24 VOLT WIRING
FIELD SUPPLIED LINE VOLTAGE WIRING
FACTORY SUPPLIED LINE VOLTAGE WIRING
WIRING LEGEND
G0642663
A
55455
REV
DRAWING NO
TITLE
CAGE CODE
COLUMBUS, OHIO 43229
P.O. BOX 29186
1050 DEARBORN DRIVE
TRACER COLOR
GN / Y
INSULATION COLOR
W - WHITE
BK - BLACK
BL - BLUE
Y - YELLOW
GN - GREEN
P - PURPLE
BR - BROWN
R - RED
OR - ORANGE
WIRE COLOR CODE
CONSENT OF LIEBERT CORPORATION
USED WITHOUT THE EXPRESS WRITTEN
DISCLOSED TO OTHERS OR DUPLICATED OR
INFORMATION CONTAINED THEREIN SHALL BE
CORPORATION AND NEITHER IT NOR THE
PROPRIETARY INFORMATION OF LIEBERT
THIS DOCUMENT CONTAINS CONFIDENTIAL AND
DLT2
38-1
TH/HU
TEMP/
HUMD
SENSORS
ANALOG
INPUTS #1
ANALOG
INPUTS #2
INTELLISLOT 1
INTELLISLOT 2
INTELLISLOT
POWER
SUPPLY
PRIMARY P65 CONNECTION
UNITDISPLAY
UNITALARM
P64 WIRES
INOLUDED
ONLARGE
DISPLAY
ONLY
Figure 4 Circuit diagram
Liebert.PEX2 Series Air Conditioner User Manual
Содержание Liebert PEX Series