Power On Procedure
F-3
Power-on and Power-off Procedures
Follow these steps to power the EC-1100 on:
1. Connect one power cord to a facility outlet.
2. Connect the second power cord to a separate facility power
source.
For redundancy and maximum availability, ensure each receptacle is
connected to a separate facility power source.
3. Turn on the power switch in each component in the cabinet.
• The ED-1032 power switch is shown in Figure F-1
• The Ethernet hub does not have a power switch; power is
supplied through the AC cable.
• The Connectrix service processor power switch is located on
the right side.
4. Turn the master power switches to the
ON
position.
All cabinet components should now be powered on. If a unit does not
have power, verify the following:
•
The unit is turned on.
•
The master power switch(es) is/are in the
ON
position.
•
All power cords are secure at both ends.
•
The plugs on the AC power input are secure in the facility power
source.
•
There is power to the facility power source.
Power-On Self Tests
When powered on, the ED-1032 performs power-on self tests
(POSTs), during which:
1. The Power LED on the operator panel illuminates (green).
2. The System Error LED on the operator panel illuminates (amber).
3. System service processor (SSP) messages appear on the top line of
the operator panel status display, indicating POST and load
sequences.
Содержание Connectrix EC-1100 System
Страница 4: ...Connectrix EC 1100 System User Guide iv...
Страница 8: ...Connectrix EC 1100 System User Guide viii Contents...
Страница 12: ...xii Connectrix EC 1100 System User Guide Figures...
Страница 14: ...xiv Connectrix EC 1100 System User Guide Tables...
Страница 22: ...xxii Connectrix EC 1100 System User Guide Warnings and Cautions...
Страница 78: ...2 2 46 Connectrix EC 1100 System User Guide Connectrix Manager Administration...
Страница 83: ...3 Fabric Manager Views 3 5 Fabric Manager Figure 3 3 Zoning View Showing Active Zone Set...
Страница 92: ...3 3 14 Connectrix EC 1100 System User Guide Fabric Manager...
Страница 128: ...4 4 36 Connectrix EC 1100 System User Guide Fabric Zoning...
Страница 140: ...5 5 12 Connectrix EC 1100 System User Guide Connectrix Manager Logs...
Страница 196: ...F F 6 Connectrix EC 1100 System User Guide Power on and Power off Procedures...
Страница 212: ...s 4 Connectrix EC 1100 System User Guide Sales and Service Locations...