13
G
B
PRECAUTIONS
1
An ACOUSTIC PRESSURE value of 4 m. corresponds to the ACOUSTIC
POWER value stated on the yellow label located on the compressor,
minus 20 dB
THINGS TO DO
•
The compressor must be used in a suitable environment (well
ventilated with an ambient temperature of b5°C and +40°C)
and never in places affected by dust, acids, vapors, explosive or
flammable gases
.
• Always maintain a safety distance of at least 4 meters between the
compressor and the work area.
• Any coloring of the belt guards of the compressor during painting operations
indicates that the distance is too short.
• Insert the plug of the electric cable in a socket of suitable shape, voltage
and frequency complying with current regulations.
• For three-phase versions have the plug fitted by a qualified electrician
according to local regulations. The first time you start the compressor,
check that the direction of rotation is correct and matches that indicated by
the arrow on the conveyor (
Fig. 1
, the air must be conveyed towards the
head of the compressor).
• Use extension cables with a maximum length of 5 meters and of suitable
cross-section.
• The use of extension cables of different length and also of adapters and
multiple sockets should be avoided.
• Always use the switch of the pressure switch to switch off the compressor
• Always use the handle to move the compressor.
• When operating, the compressor must be placed on a stable, horizontal
surface to guarantee correct lubrication.
THINGS
NOT
TO DO
• Never direct the jet of air towards persons, animals or your body. (Always
wear safety goggles to protect your eyes against flying objects that may be
lifted by the jet of air).
• Never direct the jet of liquids sprayed by tools connected to the compressor
towards the compressor.
• Never use the appliance with bare feet or wet hands or feet.
• Never pull the power cable to disconnect the plug from the socket or to
move the compressor.
• Never leave the appliance exposed to adverse weather conditions.
• Never transport the compressor with the receiver under pressure.
• Do not weld or machine the receiver. In the case of faults or rusting, replace
the entire receiver.
• Never allow inexpert persons to use the compressor. Keep children and
animals at a distance from the work area.
• Do not position flammable or nylon/fabric objects closed to and/or on the
compressor.
• Never clean the compressor with flammable liquids or solvents. Check that
you have unplugged the compressor and clean with a damp cloth only.
• The compressor must be used only for air compression. Do not use the
compressor for any other type of gas.
• The compressed air produced by the compressor cannot not be used
for pharmaceutical, food or medical purposes except after particular
treatments and cannot be used to fill the air bottles of scuba divers.
THINGS YOU SHOULD KNOW
•
To avoid overheating of the electric motor, this compressor is
designed for intermittent operation as indicated on the technical
dataplate (for example, S3-25 means 2.5 minutes ON, 7.5 minutes
OFF). In the case of overheating, the thermal cutout of the motor
trips, automatically cutting off the power when the temperature is
too high. The motor restarts automatically when normal temperature
conditions are restored
.
• To facilitate restart of the compressor, in addition to the operations
indicated, it is important to return the button of the pressure switch to the
OFF position and then to ON again (
figures 2-3-4
).
• On certain «V» type versions, the reset button on the terminal box of the
motor must be pressed (
fig. 5
).
• On three-phase versions, simply return the button of the pressure switch
to the ON position. (
fig. 3
).
• Single-phase versions are fitted with a pressure switch equipped with a
delayed closing air discharge valve which facilitates start-up of the motor.
Therefore venting of air from this valve for a few seconds with the receiver
empty is normal.
• All the compressors are fitted with a safety valve that is tripped in the case
of malfunctioning of the pressure switch in order to assure machine safety.
• When fitting a tool, the flow of air in output must be switched off.
• When using compressed air, you must know and comply with the safety
precautions to be adopted for each type of application (inflation, pneumatic
tools, painting, washing with water-based detergents only, etc.).
START-UP AND USE
2
• Fit the wheels and foot (or the suckers according to model) following the
instructions provided in the packaging.
• Check for correspondence between the compressor plate data with the
actual specifications of the electrical system. A variation of ± 10% with
respect of the rated value is allowed.
• Insert the plug of the power cable in a suitable socket (
fig. 6
) checking that
the button of the pressure switch located on the compressor is in the OFF
«O» position.
• For lubricated models, check the oil level using the rod included in the oil
fuel plug (
figures 7a-7b-7c
) or the sight glass (
fig. 7d
), and if necessary
top up.
• At this point, the compressor is ready for use.
• Operating on the switch of the pressure switch (
fig. 3
), the compressor
starts, pumping air into the receiver through the delivery pipe.
• When the upper calibration value (set by the manufacturer) has been
reached, the compressor stops, venting the excess air present in the
head and in the delivery pipe through a valve located under the pressure
switch.
This facilitates subsequent restart due to the absence of pressure in the
head. When air is used, the compressor restarts automatically when the
lower calibration value is reached (2 bar between upper and lower).
• The pressure in the receiver can be checked on the gauge provided (
fig. 8
).
• The compressor continues to operate according to this automatic cycle
until the switch of the pressure switch is turned.
• Always wait at least 10 seconds from when the compressor has been
switched off before restarting this.
• All compressors are fitted with a pressure reducer. Operating on the knob
with the tap open (pulling it up and turning it in a clockwise direction to
increase the pressure and in a counterclockwise direction to reduce this
fig. 9a
), air pressure can be regulated so as to optimize use of pneumatic
tools. After setting the value required, push the knob to fasten this (
fig. 9b
).
On some versions, the ring-nut underneath must be tightened to fasten the
knob (
figures 9c-9d
).
• The value set can be checked on the gauge.
•
Please check that the air consumption and the maximum working
pressure of the pneumatic tool to be used are compatible with the
pressure set on the pressure regulator and with the amount of air
supplied by the compressor.
• Always pull out the plug and drain the receiver once you have completed
your work (
figures 10-11
).
AIR RECEIVER (ON TANK-MOUNTED UNITS)
3
• Corrosion must be prevented: depending on the conditions of use,
condensate may accumulate inside the tank and must be drained every
day. This may be done manually, by opening the drain valve, or by means
of the automatic drain, if fitted to the tank. Nevertheless, a weekly check of
correct functioning of the automatic valve is needed. This has to be done
by opening the manual drain valve and check for condensate (
fig. 11
).
• Periodical service inspection of the air receiver is needed, as internal
corrosion can reduce the steel wall thickness with the consequent risk
of bursting. Local rules need to be respected, if applicable. The use of
the air receiver is forbidden once the wall thickness reaches the minimum
value as indicated in the service manual of the air receiver (part of the
documentation delivered with the unit).
• Lifetime of the air receiver mainly depends on the working environment.
Avoid installing the compressor in a dirty and corrosive environment, as
this can reduce the vessel lifetime dramatically.
• Do not anchor the vessel or attached components directly to the ground
or fixed structures. Fit the pressure vessel with vibration dampers to avoid
possible fatigue failure caused by vibration of the vessel during use.
• Use the vessel within the pressure and temperature limits stated on the
nameplate and the testing report.
• No alterations must be made to this vessel by welding, drilling or other
mechanical methods.
Preserve this handbook for future reference
Содержание E 241
Страница 1: ...Rheinland Elektro Maschinen group www rem maschinen com KOMPRESOREN MIT DIREKTANTRIEB E 241...
Страница 2: ......
Страница 3: ...1 7a 6 2 7b 7c 3 4 5...
Страница 4: ...8 9b 9a 11 9d 10 9c 7d OIL LEVEL...
Страница 5: ...12b 12a 14b 14a 13c 13b 12c 13a...
Страница 45: ...45 R U S 1 4 m 20 dB 5 C 40 C 3 1 5 1 5 S3 25 2 5 7 5 2 3 4 V 5 3 2 10 6 O OFF 7a 7b 7c 7d 3 2 8 10 9a 9b 9c 9d...
Страница 53: ...53 B G 1 4 20 dB 5 C 40 C 3 1 5 1 5 S3 25 2 5 7 5 2 3 4 V 5 3 2 10 6 OFF 7 7b 7c 7d 3 2 8 10 9 9b 9c 9d 10 11...
Страница 63: ...1 4 20 5 40 4 1 5 S3 25 2 5 7 5 OFF ON 2 3 4 V 5 ON 3 2 10 6 OFF O 7 7 7 7 3 2 8 10 10 11 3 11 5...
Страница 64: ...9 9 9 9 5...
Страница 66: ...12...
Страница 67: ...45 66719389...
Страница 68: ...63 230 V Ac 50 Hz 120 V Ac 60 Hz 230 V Ac 50 Hz 120 V Ac 60 Hz...
Страница 80: ......