35
Functional principle of the joker² light barrier system
Copyright eltima electronic 2022
Synchronization of step chains
Name:
synchron
, Levels:
-
Values:
no,
yes
Default setting:
no
If several step chains are used in parallel, they very likely will have a different
total duration, either because they consist of a different number of steps, or
because the step duration of the participating steps is different.
In order to repeat such step chains or to run them in an endless loop, the
new cycle must not start before the end of the longest chain is reached. This
is ensured by the parameter
synchronization
.
In order to synchronize several step chains, the parameter
synchroniza-
tion
must be set to
yes
in the first step of each of these chains.
This way the chains with the shorter total duration will wait for the slowest
one, after which all chains start at the same time.