Programming examples
Copyright eltima electronic 2022
Digital Part
Output a reacts to the trigger 2
, triggered by the action mode and
switches immediately for 200 ms
. However, the output does not react to
trigger 5
because the interval
has not yet elapsed. At the earliest after
the time of 800 ms a next trigger could cause a new switching operation.
Output b also reacts to the trigger 2
, i.e. the action mode is met. First,
the delay time
of 200 ms elapses, then the output switches twice
for
200 ms, with a period
of 300 ms and is ready for a new trigger at the time
of 1000 ms after the interval
has elapsed.
Output c reacts to the trigger 2
, triggered by the light barrier 2 and
switches immediately at 100 ms for 200ms
.
Because the release time
, period
and the interval
are equal, the
output is immediately ready for a new trigger. This is set at 500 ms.
Output d reacts to the trigger 3
, triggered by the light barrier 3 at 2 sec-
onds (note: the time axis of the output d is specified in seconds). The output
switches immediately for 200 ms
and waits for the interval
of 2 sec-
onds to elapse. Because the light barrier is still interrupted hereafter, a new
cycle begins and the output switches again. This continues as long as the light
barrier 3 is interrupted.