48
Programming examples
Copyright eltima electronic 2022
Taking pictures using the factory settings
The following table shows the factory settings of the basic and output pa-
rameters:
Operation principle of the factory settings:
The interruption of the light barrier
at the time of 0 ms leads to an imme-
diate trigger
, because no dwell time
is programmed. Subsequently all
outputs will switch to ON immediately for 250 ms
, because there is no
lag time
programmed. A second interruption of the beam at 270 ms leads
to a new trigger, which is not accepted since the time for the interval
has
not yet expired. Only the next interruption at the time of 600 ms leads to a
new release, because all times have elapsed and the light barrier was free
again.
Since the parameter
drive mode
is set to
single
and because no repeti-
tions are set, the programmed cycle runs once.
The light barrier system triggers regardless of a time window, because the
start and end time of the time window are the same.
Basic Parameters
Value
action mode
one beam barrier
sensitivity 1 - 3
6
range
distance
dwell time
0 ms
scanning mode
with reflector
Output parameters
a
b
c
d
lag time
0 ms
0 ms
0 ms
0 ms
release time
250 ms
250 ms
250 ms
250 ms
release period
350 ms
350 ms
350 ms
350 ms
interval
350 ms
350 ms
350 ms
350 ms
repetitions
0
0
0
0
trigger
act mode
act mode
act mode
act mode
drive mode
single
single
single
single
wake-up
0
0
0
0
start time
00 00 00
00 00 00
00 00 00
00 00 00
end time
00 00 00
00 00 00
00 00 00
00 00 00
link
no link
no link
no link
no link
open shutter
0
0
0
0
Figure 30: Sequence diagram with the factory settings
Light-barri-
ers
output a
output b
output c
output d