40
Functional principle of the joker² light barrier system
Copyright eltima electronic 2022
Resetting the parameters
Name:
Res Para
, level:
Values:
no
yes
Default setting:
no
When setting the parameters, typing or thinking errors can creep in and the
light barrier system may not react at all as expected. This can be for example,
due to the fact that one or more parameters have values that are unsuitable
for the intended purpose. Other sources of error can also be incorrect units
of measurement or mismatched triggers.
If the search for the cause of a strange behaviour gets difficult, all parameters
of the basic level, the outputs and the X-parameters can be reset to the de-
livery status. Then the light barrier system will behave again "normally", and
the program can be entered again.
To reset all user parameters, set the parameter
res para
to
yes
and press
the
key. After the reset operation is completed, the parameter will be
reset to
no
.
Reset to factory
Name:
Res fact
, level:
Values:
no
yes
Default setting:
no
This parameter resets all parameters, including the system parameters, to
the delivery state.
To reset the parameter, set the parameter
res fact
to
yes
and press the
key.
Software version:
Name:
Soft-Ver
, level:
The parameter displays the software version and can only be read.