39
Functional principle of the joker² light barrier system
Copyright eltima electronic 2022
Speed measurement
Name:
meas spe
, level:
Default setting:
0
range
unit
step
0- 999
mm
1
The jok
e
r
²
light barrier system, can measure the speed of an object breaking
through the light beams.
To measure the speed, proceed as follows:
Set up light barrier 1 and 2 with the beams parallel to each other.
Measure the distance between the two beams and set the parameter
mes spe
to this value.
Carry out the training process.
Let an object interrupt the light beams.
Read the speed on the display.
Unit for speed measurement
Name:
Unit
, level:
Values:
km/h
,
m/s
Basic setting:
km/h
The parameter specifies the unit in which the speed should be displayed.
Language
Name:
Language,
level:
Values:
Deutsch
,
English
,
Francais
,
Italiano
,
Nederlands
,
Span-
ish
,
Letzebuerg
,
Portugues
Default setting:
deutsch
The light barrier system currently supports the following languages: German,
English, French, Italian, Dutch, Spanish and Luxembourgish.