Functional principle of the joker² light barrier system
Copyright eltima electronic 2022
ON time
Name:
ON time
, Levels:
-
Default setting:
250 ms
range
unit
step
0- 8800
µs
200 µs
0 - 9999
ms
1 ms
0 - 3600
s
1 s
0 - 60
min
1 min
The
ON time
is the time for which the specified switch or switches are
closed. A connected device is active during this time.
Important: Delay and ON-time together must not be longer than the
step duration! Values for the delay or ON-time whose sum is greater
than the step duration, will not be accepted. The step duration must
be modified first!
Step duration
Name:
step dur
, Levels:
-
Default setting:
500 ms
range
unit
step
0- 8800
µs
200 µs
0 - 9999
ms
1 ms
0 - 3600
s
1 s
0 - 60
min
1 min
The
step duration
specifies the total duration of a step.
In order to calculate the total length of a step chain, the step duration
of the participating steps must be added.