Functional principle of the joker² light barrier system
Copyright eltima electronic 2022
Scanning mode
Name
Default setting
Range
Level
scan 1
with refl
with refl,
without ref,
passive
scan 2
with refl
ditto
scan 3
with refl
ditto
This parameter defines the scanning method for the three light barriers, and
has three different settings.
The typical scanning method is "
with reflector
". In this case, as already
described, the light barrier works with a reflector. This setup allows for an
extremely accurate switching point and a very high repeatability. In addition,
the working distance is greatest when using a reflector.
When working
without a reflector
the subject acts as reflector. As soon
as a certain amount of light, which is determined by the parameter
sensi-
tivity
is detected by the receiver, a trigger will be issued.
In the mode
without reflector
the range essentially depends on the re-
flective properties of the subject. It is recommended to set the scanning
method to
distance
.
Since no defined beam is interrupted in this operating mode and the reflec-
tion of the beam depends very much on the geometry of the subject, the
switching point cannot be predicted as precisely, and some subjects may be
missed.
Nevertheless, working without a reflector can be very useful in situa-
tions where no high range is required and the installation of a reflec-
tor causes problems. In that case, the inaccuracy of the switching
point can be accepted and compensated with a higher depth of field.
In the
passive
scanning mode the IR transmitter is shut down and the re-
ceiver waits for rapid changes of light in the infrared range. This mode allows,
for example, pictures of lightning by day or by night.