Functional description
5
gas-lab
Q1
Page 77
Limit
The
Limit
menu item indicates the currently set limit value of the limit
monitoring or the maximum permissible change of the measurement
within a parameterised monitoring period when monitoring gradients.
This dialog allows disabling single messages via the operator panel. It is
also possible the change the limit value to be monitored in case of
measurement monitoring messages. However, the numerical locks must
have been opened for such actions to be carried out.
Disabled messages
The
Disabled messages
menu
refers to the message processing of the
monitoring module. The corresponding display lists all currently disabled
single messages. Additional information indicated on the display comprises
the type of the message, the real message status before the disabling, and
possibly the counter for a monitored minimum pending time.
The
Disabled messages
menu described here merely provides information.
Please switch to the
Single messages
menu (see above) if you want to
change the status of a single message (disabled / enabled).
Pressing the Enter key opens
the selection list containing all
currently blocked messages.
Limit, here: upper limit value.
Note: An additional hysteresis may have been adjusted via PC and with the
parameterisation program to avoid fluttering messages