View and design
2
gas-lab
Q1
Page 9
All in all, up to 6 process boards can be mounted in the broader housing and up
to 3 boards in the narrow design. Please see Section
Fehler! Verweisquelle
konnte nicht gefunden werden.
or the Technical Data Section in Chapter 10
for a description of the currently available boards.
The following illustration shows, as an example, a device in the narrow design
with the always existing LMFA7 board.
gas-net
Q1 rear view (example)
0,63 ATT
LE
LA
D1
D2
D3
I1+
I3+
I-
SH
DC
LMFA7
SH
GD
DT
VN
VP
PE
DCF77
24V
HS-Bus
2
M
O
C
G
f
S
D
CD
RI
TX
RX
SD
DD
SH
DH
internal
Board 3
Board 2
Board 1
Output board LMFA7 (digital/analog)
LA/LE:
D1-D3: Three digital outputs for digital signals / pulses.
I1-I3:
Three analog outputs for measurement output.
optical fibre connection for external I/O expansion
(sensor system connection)
Any
input or output board can
be assigned to board locations 1 or 2.
gas-net