PG4UW
Supply voltage
(in mV) - supply voltage in target system. Control program checks or sets (it
depends on programmer type) entered supply voltage in target system before every action on
device.
Disable test supply voltage
- disables measure and checking supply voltage of
programmed device, set in Supply voltage edit box, before action with device.
Delay after reset active
- this parameter determine delay after Reset signal active to start
action with device. This delay depends on values of used devices in reset circuit of device
and can be chosen from these values: 10ms, 50ms, 100ms, 500ms or 1s.
I
nactive level of ISP signals
- this parameter determine level of ISP signals after finishing
access to target device. Signals of ISP connector can be set to Pull-up (signals are tied
through 22k resistors to supply voltage) or Pull-down (signals are tied through 22k resistors to
ground).
Keep ISP signals at defined level after operation
- enables keeping set level of ISP signals
after access to target device finished. Control program indicates activated pull-up/pull-down
resistors by displaying window with warning. After user close this window control program will
deactivate resistors.
group
Programming parameters
This group is available for some types of devices. It contains settings of which device parts or
areas has to be programmed.
group
Erase parameters
This group is available for some types of devices. It contains special settings of erase modes
of selected device.
Device / Device options / Serialization
Serialization is special mode of program. When a serialization mode is activated, a specified
value is automatically inserted on predefined address into buffer before programming each
device. When more devices are programmed one by one, the serial number value is changed
for each device automatically and inserted into buffer before programming device, so each
device has unique serial number.
There are three types of serialization:
•
Incremental mode
•
From file mode
•
Custom generator mode
Dialog
Serialization
contains also settings for associated serialization position files that are
used with project files with serialization turned on. For more detailed information about using
serialization in project files, look at Serialization and projects.
Basic rules of serialization:
If a new device is selected, the serialization function is set to a default state i.e. disabled.
95
Содержание DATAMAN-40PRO
Страница 7: ...Quick Start Introduction 7...
Страница 12: ...Quick Start 12...
Страница 14: ...4 check if the device is blank click on 5 program device click on 6 additional verify of device click on 14...
Страница 15: ...Detailed description Detailed description 15...
Страница 16: ...DATAMAN 448PRO2 16...
Страница 29: ...DATAMAN 48PRO2 DATAMAN 48PRO2C DATAMAN 48PRO2 DATAMAN 48PRO2C 29...
Страница 44: ...DATAMAN 40PRO 44...
Страница 53: ...DATAMAN MEMPRO DATAMAN MEMPRO 53...
Страница 60: ...Setup 60...
Страница 64: ...Step 6 Check your setting and then click on Install button Step 7 Installation process will start 64...
Страница 69: ...Setup Step 6 Click on Continue Anyway button For Windows Vista Click Install this driver software anyway 69...
Страница 71: ...PG4UW PG4UW 71...
Страница 138: ...PG4UWMC 138...
Страница 148: ...Common notes 148...
Страница 159: ...Troubleshooting and warranty Troubleshooting and warranty 159...