The final Job Report file name of new report will be:
d:\job_reports\job_report_001_myproject.jrp
Note, the order inside file name is incremented by 1.
When
Automatically save Job Report file
setting is set, no Job Report dialogs appears
when generating Job Report. Newly generated Job Report is saved to file without any dialogs
or messages (if no error occurs while saving to file).
If the checkbox
Automatically save Job Report file
is unchecked, the PG4UW will show
Job Report dialog every time needed.
In the Job Report dialog user can select operation to do with Job Report. If user selects no
operation (Close button), the Job Report will be written to PG4UW Log Window only.
Automatic YES!
Allows user to override default settings (as preset in PG4UW software) of indication for the
state when the programmer and the software wait for withdrawing programmed device and a
new one will be inserted in active Automatic YES! mode.
Default (as preset in software)
- the programmer indicates the state when a device is
programmed and the programmer with software wait for inserting a new device as preset in
the software for respective programmer. Multi-sockets programmers (the programmers with
more than one ZIF socket) do not indicate this state, see description for
Not indicated (quiet
mode)
. Single-socket programmers (the programmers with one ZIF socket) indicate this state
by LED Busy blinking, see description for
By LED Busy blinking
setting.
Not indicated (quiet mode)
– the programmer, regardless of the number of ZIF sockets of
the programmer, does not indicate the state when a device is programmed and the
programmer with software wait for inserting a new device. After an operation with a device
only one of the status LEDs Error or OK lights, in dependence on the result of previous
operation. This LED goes off immediately after detecting removal of a device from the ZIF
socket.
By LED Busy blinking
- the programmer, regardless of the number of ZIF sockets of the
programmer, indicates the state when a device is programmed and the programmer with
software wait for inserting a new device mode by blinking with the LED Busy. After an
operation with a device is done, one of the status LEDs (OK or Error) lights, in dependence
on the result of previous operation and the LED Busy is blinking. If the program detects
removal of a device from ZIF socket, then the status LED goes off, but the LED Busy is still
blinking to indicate readiness of the program to repeat last operation with new device. After
the program indicates one or more pins of (new) device in the ZIF socket, the LED Busy goes
light continually. From this point the program waits a requested time for insertion of the rest
pins of new device. If a requested time (Device insertion complete time) overflows and a
device is not correctly inserted, the program will light the LED Error to indicate this state.
When new device is inserted correctly, the status LED goes off and a new operation with
device is started.
Remote control
Remote control of PG4UW control program allows to control some functions of PG4UW
application by other application. This is very suitable feature for integrating device
programmer to mass-production handler system or other useful application.
128
Содержание DATAMAN-40PRO
Страница 7: ...Quick Start Introduction 7...
Страница 12: ...Quick Start 12...
Страница 14: ...4 check if the device is blank click on 5 program device click on 6 additional verify of device click on 14...
Страница 15: ...Detailed description Detailed description 15...
Страница 16: ...DATAMAN 448PRO2 16...
Страница 29: ...DATAMAN 48PRO2 DATAMAN 48PRO2C DATAMAN 48PRO2 DATAMAN 48PRO2C 29...
Страница 44: ...DATAMAN 40PRO 44...
Страница 53: ...DATAMAN MEMPRO DATAMAN MEMPRO 53...
Страница 60: ...Setup 60...
Страница 64: ...Step 6 Check your setting and then click on Install button Step 7 Installation process will start 64...
Страница 69: ...Setup Step 6 Click on Continue Anyway button For Windows Vista Click Install this driver software anyway 69...
Страница 71: ...PG4UW PG4UW 71...
Страница 138: ...PG4UWMC 138...
Страница 148: ...Common notes 148...
Страница 159: ...Troubleshooting and warranty Troubleshooting and warranty 159...