![Elnec DATAMAN-40PRO Скачать руководство пользователя страница 153](http://html1.mh-extra.com/html/elnec/dataman-40pro/dataman-40pro_user-manual_2395135153.webp)
Common notes
/Close
This parameter has sense together with /Program parameter only,
and makes program PG4UW to close automatically after device
programming is finished (no matter if operation was successful or
not).
/Saveproject:<file_name>
The command is used to save currently selected device type, buffer
contents and configuration to project file. Command /Saveproject:... is
equivalent to user selected command Save project in PG4UW control
program.
/Eprom_Flash_Autoselect[:xx]
Forces automatic select EPROM or FLASH type by reading of
electronic ID from the chip, inserted currently in ZIF socket of
programmer. Optional parameter xx means pins number of device in
ZIF (this time are valid 28 or 32 pins only) and it is required just for
older programmers without insertion test capability. For others
programmers the xx parameter can be omitted, because is ignored.
Examples:
/Eprom_Flash_Autoselect
/Eprom_Flash_Autoselect:32
/writebuffer:ADDR1:B11,B12,B13,B14,...,B1N[::ADDR2:B21,B22,B23,B24,...,B2M]...
Command /writebuffer is used to write block of Bytes to PG4UW main
buffer at specified address. Write buffer command has one block of
data required and other block(s) of data (marked with [...]) optional.
Please do not use spaces or tabs in the command.
Buffer address is always defined as Byte address, it means, that for
buffer organization x16, the address AAAAx16 in buffer has to be
specified in command /writebuffer as 2*AAAA (x8).
Example 1:
/writebuffer:7FF800:12,AB,C5,D4,7E,80
Writes 6 Bytes 12H ABH C5H D4H 7EH 80H to buffer at address 7FF800H.
The addressing looks like following:
the first Byte at the lowest address
Buffer Address Data
7FF800H 12H
7FF801H ABH
7FF802H C5H
7FF803H D4H
7FF804H 7EH
7FF805H 80H
Example 2
:
/writebuffer:7FF800:12,AB,C5,D4,7E,80::FF0000:AB,CD,EF,43,21
\_____________________/ \___________________/
the first block of data the second block of data
Writes two blocks of data to buffer.
The first block of data - 6 Bytes 12H ABH C5H D4H 7EH 80H are written to buffer
at address 7FF800H in the same way as in Example 1.
The second block of data - 5 Bytes ABH CDH EFH 43H 21H are written to buffer
at address FF0000H.
The addressing looks like following:
the first Byte at the lowest address
153
Содержание DATAMAN-40PRO
Страница 7: ...Quick Start Introduction 7...
Страница 12: ...Quick Start 12...
Страница 14: ...4 check if the device is blank click on 5 program device click on 6 additional verify of device click on 14...
Страница 15: ...Detailed description Detailed description 15...
Страница 16: ...DATAMAN 448PRO2 16...
Страница 29: ...DATAMAN 48PRO2 DATAMAN 48PRO2C DATAMAN 48PRO2 DATAMAN 48PRO2C 29...
Страница 44: ...DATAMAN 40PRO 44...
Страница 53: ...DATAMAN MEMPRO DATAMAN MEMPRO 53...
Страница 60: ...Setup 60...
Страница 64: ...Step 6 Check your setting and then click on Install button Step 7 Installation process will start 64...
Страница 69: ...Setup Step 6 Click on Continue Anyway button For Windows Vista Click Install this driver software anyway 69...
Страница 71: ...PG4UW PG4UW 71...
Страница 138: ...PG4UWMC 138...
Страница 148: ...Common notes 148...
Страница 159: ...Troubleshooting and warranty Troubleshooting and warranty 159...