![Elnec DATAMAN-40PRO Скачать руководство пользователя страница 142](http://html1.mh-extra.com/html/elnec/dataman-40pro/dataman-40pro_user-manual_2395135142.webp)
•
If the checkbox is checked, the project file for Site #1 will be used also for all other
Programmer Sites. In this mode all Sites are using the same shared buffer of project data
and program the same device type.
•
If the checkbox is not checked, each Site will use its own project file defined by name in
table of Sites in column Project file. In this mode each Site is using its own buffer of
project data, which allows to program different data to different types of devices at the
same time in each Site.
Checkbox Automatic YES!
Automatic YES! checkbox - when checked, Automatic YES! is set on for all programmers. For
more details about Automatic YES! feature see Programmer / Automatic YES. This feature
may not be available for some types of programmers.
Panel Timer refresh rate settings
Timer refresh rate defines how often the PG4UWMC program will request status information
from running Programmer Sites. Status information means current device operation type,
progress, result and so on. Current status information is displayed in main window of
PG4UWMC. The default timer refresh rate value is 200ms. If you wish faster refresh of status
information displayed in Operation panel of PG4UWMC, select shorter refresh interval. If you
notice the system performance slow down, when using faster refresh, select higher refresh
value to make refresh less often. On the Pentium 4 computers there is almost no
performance penalty depending on timer refresh rate but on slower computers it is sometimes
useful to select longer (less often) timer interval.
Panel Log file settings
are used to set mode of using Log file report
Log file is text file containing information about PG4UWMC control program operation flow,
which means information about loading project files, device operation types and device
operation results. Multiprogramming system generates few of Log files. One main Log file of
program PG4UWMC and Log files for each of running Programmer Sites. Each Site has its
own one Log file. The name of Site's Log file has the same prefix as the name of Log file
specified in edit box Log file. The file name prefix is followed by the number of Site in the form
of _#<Snum>.
Example:
142
Содержание DATAMAN-40PRO
Страница 7: ...Quick Start Introduction 7...
Страница 12: ...Quick Start 12...
Страница 14: ...4 check if the device is blank click on 5 program device click on 6 additional verify of device click on 14...
Страница 15: ...Detailed description Detailed description 15...
Страница 16: ...DATAMAN 448PRO2 16...
Страница 29: ...DATAMAN 48PRO2 DATAMAN 48PRO2C DATAMAN 48PRO2 DATAMAN 48PRO2C 29...
Страница 44: ...DATAMAN 40PRO 44...
Страница 53: ...DATAMAN MEMPRO DATAMAN MEMPRO 53...
Страница 60: ...Setup 60...
Страница 64: ...Step 6 Check your setting and then click on Install button Step 7 Installation process will start 64...
Страница 69: ...Setup Step 6 Click on Continue Anyway button For Windows Vista Click Install this driver software anyway 69...
Страница 71: ...PG4UW PG4UW 71...
Страница 138: ...PG4UWMC 138...
Страница 148: ...Common notes 148...
Страница 159: ...Troubleshooting and warranty Troubleshooting and warranty 159...