Note:
Characters 0 and 1 immediately changes content of edit area.
Buffer / Fill block
Selecting this command causes filling selected block of buffer by requested hex (or ASCII)
string.
Selecting option "Allow address history logging" activates saving of recently confirmed values.
These are saved for each device separately, count is limited to last 15 items.
Note:
Address history values are common for all buffer data manipulation dialogs.
Default address range is set according to buffer range of selected device.
Selecting option "Maintain last inserted values" causes that for the next time you open this
dialog, previously confirmed values will be reloaded as default.
Buffer / Copy block
This command is used to copy specified block of data in current buffer on new address.
Target address needn't be out from source block addresses.
Buffer / Move block
This command is used to move specified block of data in current buffer on new address.
Target address needn't be out from source block addresses. Source address block (or part)
will be filled by topical blank character.
Selecting option "Allow address history logging" activates saving of recently confirmed values.
These are saved for each device separately, count is limited to last 15 items.
Note:
Address history values are common for all buffer data manipulation dialogs.
Default address range is set according to buffer range of selected device.
Selecting option "Maintain last inserted values" causes that for the next time you open this
dialog, previously confirmed values will be reloaded as default.
Buffer / Swap block
This command swaps a high- and low- order of byte pairs, foursomes or nibbles inside bytes
depending on swap mode selected by user. Swap operation is performed on buffer block
specified by Start and End addresses. This block must start on even address and must have
an even number of bytes. If the conditions do not fulfill, the program modifies addresses itself
(start address is moved on lower even address and/or end address is moved on higher odd
address).
Following swap modes are available, user can select from:
1. Swap 2-bytes inside 16-bit words swap of byte pairs inside 16-bit words.
2. Swap 4-bytes inside 32-bit words swap of byte foursomes inside 32-bit words.
3. Swap nibbles inside bytes
swap of high- and low- nibbles inside each byte.
4.Mirror bits inside bytes
mirror bits inside each byte
Examples of swap operation in buffer:
84
Содержание DATAMAN-40PRO
Страница 7: ...Quick Start Introduction 7...
Страница 12: ...Quick Start 12...
Страница 14: ...4 check if the device is blank click on 5 program device click on 6 additional verify of device click on 14...
Страница 15: ...Detailed description Detailed description 15...
Страница 16: ...DATAMAN 448PRO2 16...
Страница 29: ...DATAMAN 48PRO2 DATAMAN 48PRO2C DATAMAN 48PRO2 DATAMAN 48PRO2C 29...
Страница 44: ...DATAMAN 40PRO 44...
Страница 53: ...DATAMAN MEMPRO DATAMAN MEMPRO 53...
Страница 60: ...Setup 60...
Страница 64: ...Step 6 Check your setting and then click on Install button Step 7 Installation process will start 64...
Страница 69: ...Setup Step 6 Click on Continue Anyway button For Windows Vista Click Install this driver software anyway 69...
Страница 71: ...PG4UW PG4UW 71...
Страница 138: ...PG4UWMC 138...
Страница 148: ...Common notes 148...
Страница 159: ...Troubleshooting and warranty Troubleshooting and warranty 159...