![Electrolux WTM165ERA Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/electrolux/wtm165era/wtm165era_user-manual_91272037.webp)
39
ENGLISH
E8.1.3
Arrangement for solid detergent
The left and right side panels of the dishwasher have a
hose union "P" (Figure 11) for connecting the solid/
powder detergent dispensers.
To connect the dispensers, carefully carry out the fol-
lowing instructions:
•
remove protection cap "R" (Figure 11) from hose
union "P";
•
fit the solid detergent pipe, coming from the exter-
nal dispenser, on hose union "P" (Figure 12);
•
secure the pipe to the hose union with the special
clamp supplied.
Figure 11 Prearrangement for solid detergent
Figure 12 Solid detergent pipe connection
E8.1.4
Rinse aid dispensers
The machine has a nipple for the rinse aid dispenser
connection.
Carefully follow the instructions given below to cor-
rectly carry out the connection for the rinse aid:
•
remove the front panel of the rinse module;
•
remove the cover on the electrical panel;
•
release the electrical panel;
Figure 13 Rinse aid connection
•
connect the rinse aid dispenser pipe, unscrewing
plug “T” (Figure 13), always paying attention to
potential plumbing leaks (tighten the clamps
securely);
•
refit the electrical panel, its cover and the front
cover of the rinse module.
E8.2
Arrangement for electrical connection
The electrical connection of the dispenser devices
must be carried out by a specialised technician accord-
ing to that indicated below.
Detergent dispenser
•
remove the wash module panel;
•
remove the electrical panel cover;
•
connect the dispenser between terminals no. 11
and 12 on terminal block X3 or X4 (V
230Vac;PMAX 30VA);
•
refit the electrical panel cover and wash module
front panel.
Rinse aid dispenser
•
remove the rinse module panel;
•
remove the electrical panel cover;
•
connect the dispenser between terminals no. 11
and 12 on terminal block X2 (V 230Vac;PMAX
30VA);
•
refit the electrical panel cover and rinse module
front panel.
P
R
P
T
IMPORTANT!
Do not make direct connections on the
printed circuits.
IMPORTANT!
The connection cables must comply
with the standards: CEI EN 60332, CEI