14
C
TECHNICAL DATA
C1
Main technical characteristics (electric versions)
Table 1
Main technical characteristics, performance and consumption
(electric versions)
(1)
For versions without condensing unit (CU) deduct 0.13 kW.
(2)
For versions without condensing unit (CU) deduct 0.4 A.
(3)
In 165 racks/h and 200 racks/h versions the “max. power” option can be activated by means of software. In this
configuration the dishwasher will have power and absorbed current values given in Table 2. Activation of this con-
figuration is advisable whenever the dishwasher is used continuously for many hours to wash thick ceramics.
MODEL
140 racks/h
165 racks/h
180 racks/h
200 racks/h
250 racks/h
300 racks/h
MAIN T
E
CHNICA
L D
A
T
A
Power supply
Electric
Electric
Electric
Electric
Electric
Electric
Power supply voltage
V
400 3P+N
400 3P+N
400 3P+N
400 3P+N
400 3P+N
400 3P+N
Frequency
Hz
50 or 60
50 or 60
50 or 60
50 or 60
50 or 60
50 or 60
Max. power. absorbed
(1) (4)
kW
27.4 31.5
(3)
32.2
31.8
(3)
44.2
45.3
Max. current. absorbed
(2) (4)
A
41.4
48.3
(3)
48.7
50.1
(3)
68.2
70.7
Type of power cable
H07RN-F
H07RN-F
H07RN-F
H07RN-F
H07RN-F
H07RN-F
Power cable
A
5x25
5x25
5x25
5x25
5x25
5x25
Main switch
A
125A 3P+N
125A 3P+N
125A 3P+N
125A 3P+N
125A 3P+N
125A 3P+N
Supply water pressure
kPa [bar]
150..700 [1.5..7]
150..700 [1.5..7]
150..700 [1.5..7]
150..700 [1.5..7]
150..700 [1.5..7]
150..700 [1.5..7]
Hot water supply temp.
°C/°F
50/122
50/122
50/122
50/122
50/122
50/122
Cold water supply temp.
°C/°F
15/59
15/59
15/59
15/59
15/59
15/59
Concentration of chlorides in water
ppm
< 20
< 20
< 20
< 20
< 20
< 20
Electric conductivity of water
μ
S/cm
< 400
< 400
< 400
< 400
< 400
< 400
Supply water hardness
°fH/°dH/°cH
14/8/10
14/8/10
14/8/10
14/8/10
14/8/10
14/8/10
Rack loading/feed
RH machine
LH machine
From right to left
From left to right
From right to left
From left to right
From right to left
From left to right
From right to left
From left to right
From right to left
From left to right
From right to left
From left to right
No. speeds
2
2
2
2
2
2
Capacity speed 1
racks/h
80
90
110
130
160
180
Capacity speed 2
racks/h
140
165
180
200
250
300
Air emission
m
3
/h
180
180
180
180
180
180
Emitted air temperature
°C/°F
20-25/68-77
20-25/68-77
20-25/68-77
20-25/68-77
20-25/68-77
20-25/68-77
Water consumption
l/h
250
315
325
330
345
360
Equivalent sound pressure
level Leq
(5)
dB(A)
< 70
< 70
< 70
< 70
< 70
< 70
Protection rating
IPX5
IPX5
IPX5
IPX5
IPX5
IPX5
Net weight
(6)
kg
410
442
570
602
692
724
PREW
ASH
tank capacity
l
-
-
45
45
100
150
temperature
°C/°F
-
-
max. 35 / 95
max. 35 / 95
max. 35 / 95
max. 35 / 95
pump delivery
l/min
150
150
600
500 + 350
pump power
kW
-
-
0.23
0.23
2.2
2.2 + 1.1
current absorbed by pump
A
0.8
0.8
4.8
4.8 + 2.5
tank heating element
(7)
kW
-
-
10.5
10.5
16.5
16.5
module inlet minimum feed flow rate
l/min
4
4
4
4
4
4
WA
S
H
tank capacity
l
100
150
100
150
150
150
temperature
°C/°F
55-65 / 131-149
55-65 / 131-149
55-65 / 131-149
55-65 / 131-149
55-65 / 131-149
55-65 / 131-149
pump delivery
l/min
600
500 + 350
600
500 + 350
500 + 350
500 + 350
pump power
kW
2.2
2.2 + 1.1
2.2
2.2 + 1.1
2.2 + 1.1
2.2 + 1.1
current absorbed by pumps
A
4.8
4.8 + 2.5
4.8
4.8 + 2.5
4.8 + 2.5
4.8 + 2.5
tank heating element
kW
6.0 + 6.0
10.5 + 10.5
6.0 + 6.0
10.5 + 10.5
10.5 + 10.5
10.5 + 10.5
module inlet minimum feed flow rate
l/min
4
4
4
4
4
4
DUO RINSE
tank capacity
l
23
23
23
23
23
23
temperature
°C/°F
60-70 / 140-158
60-70 / 140-158
60-70 / 140-158
60-70 / 140-158
60-70 / 140-158
60-70 / 140-158
pump delivery
l/min
15
15
15
15
15
15
pump power
kW
0.35
0.35
0.35
0.35
0.35
0.35
current absorbed by pump
A
0.8
0.8
0.8
0.8
0.8
0.8
tank heating element
kW
3
3
3
3
3
3
RINSE
temperature
°C/°F
80-90 / 176-194
80-90 / 176-194
80-90 / 176-194
80-90 / 176-194
80-90 / 176-194
80-90 / 176-194
pump delivery
l/min
4
5
5
5
5
5
pump power
kW
0.35
0.35
0.35
0.35
0.35
0.35
current absorbed by pump
A
0.8
0.8
0.8
0.8
0.8
0.8
boiler heating elements
kW
6.0 + 6.0
10.5 + 6.0
10.5 + 6.0
10.5 + 6.0
10.5 + 6.0
10.5 + 6.0
boiler capacity
l
12
12
12
12
12
12
module inlet minimum feed flow rate
l/min
5
6
6
6
6
6
CU
fan motor power
kW
0.13
0.13
0.13
0.13
0.13
0.13
current absorbed by fan
A
0.4
0.4
0.4
0.4
0.4
0.4
MODEL
165 racks/h
200 racks/h
Max. power. absorbed
kW
42.0
42.3
Max. current. absorbed
A
63.4
65.2