Plumbing circuit diagram, dishwashers - 200 racks/h with CU
Plumbing circuit diagram, dishwashers - 250 racks/h without CU
LEGEND
A = Hot water inlet (~ 50°C)
B = Cold water inlet (~ 15°C)
C = Variable shutter (max 7 l/min)
M1 = Duo-Rinse pump
M2 = Rinse pump
M4 = Upper arms wash pump
M5 = Lower arms wash pump
M6 = CU fan motor
M7 = Wash pump
M8 = Prewash pump
M10 = Upper arms prewash pump
M11 = Lower arms prewash pump
ABV = Air Break Valve
YV1 = Air-Gap filling solenoid valve (20 l/min)
YV2 = Duo-Rinse tank drain solenoid valve
YV3 = Wash tank water filling solenoid valve (20 l/min)
YV4 = Wash pump discharge solenoid valve
YV5 = Wash tank drain solenoid valve
YV6 = Wash or prewash tank water filling solenoid valve (20 l/min)
YV7 = Wash or prewash pump discharge solenoid valve
YV8 = Wash or prewash tank drain solenoid valve
YV9 = Prewash tank water filling solenoid valve (20 l/min)
YV10 = Prewash pump discharge solenoid valve
YV11 = Prewash tank drain solenoid valve
YV12 = Prewash tank water filling solenoid valve (20 l/min)
YV13 = Prewash pump discharge solenoid valve
YV14 = Prewash tank drain solenoid valve
YV15 = Prewash tank water filling solenoid valve (20 l/min)
YV16 = Prewash pump discharge solenoid valve
YV17 = Prewash tank drain solenoid valve
M4
YV5
YV3
55-65°C
YV1
M2
M1
YV2
A
B
YV11
YV9
YV10
YV4
M5
Max 35°C
M6
180 m
3
/h
M8
C
ABV
ABV
60-70°C
80-90°C
M4
YV5
YV3
55-65°C
M1
YV2
YV4
M5
YV13
YV14
YV12
Max 35°C
M7
YV1
B
A
M2
ABV
C
60-70°C
80-90°C