42
E10
Installation of rack handling systems
The Manufacturer provides for the possibility of con-
necting the rack-type dishwasher to rack handling sys-
tems included in the Electrolux Professional S.p.A.
product catalogue, with the possibility of obtaining vari-
ous configurations.
The arrangements for the mechanical and electrical
connections provided for on the rack-type dishwasher
are described below: for further details on the various
types of rack handling system couplings, consult the
instructions supplied with the specific handling system
installed.
These arrangements are suitable for fitting motor-oper-
ated rack handling systems (e.g. rope conveyor belts)
and non-motor-operated rack handling systems (e.g.
rollerways, tables, etc.).
E10.1 Arrangement for mechanical connection
There are holes in the left and right side panels of the
dishwasher for carrying out the mechanical connection
of the rack handling systems.
Only use the following four holes “A” (Figure 15), what-
ever the type of system (motor-operated or not) to be
connected to the dishwasher.
Figure 15 Handling mechanical connection system
E10.2 Arrangement for electrical connection
The left and right side panels of the dishwasher have a
connector “B” (Figure 16), closed with a plug “A”
(Figure 16), to be used for carrying out the electrical
connection of the rack handling systems.
Figure 16 Handling electrical connection system
Whatever the type of system (motor-operated or not)
to be connected to the dishwasher, proceed as follows:
•
unscrew plug “A” (Figure 16) anticlockwise;
•
connect the rack handling system connector “C”
(Figure 17) to connector “B” of the dishwasher.
•
Figure 17 Detail of electrical connection
If a type “C” connector is not available for carrying out
the connection, follow the indications in the machine
wiring diagram: make sure to pass the external cable
through the special cable gland, avoiding zones where
the connection can be damaged (e.g. lower part of the
machine, due to periodical cleaning of the floor with
sweepers).
CAUTION!
Machine installation operations must
only be carried out by specialized
Technicians provided with all the
appropriate personal protection equip-
ment (safety shoes, gloves, glasses,
overalls, etc.), tools, utensils and ancil-
lary means.
IMPORTANT!
Make sure the MAIN SWITCH of the
machine is locked in the Off position -
“O”.
IMPORTANT!
Work on the electrical equipment must
only be carried out by a qualified elec-
trician.
A
A
IMPORTANT!
The rack handling system electrical
connection power lines are protected
against short circuits as shown in the
wiring diagram. However, protection
against overloads must be ensured as
provided for in point 7 of EN60204-1
(IEC 60204-1).
A
B
B
C