Extraordinary maintenance
(120-180KG)
Replacing the UV lamp
To replace the inside UV lamp, proceed as follows:
• dis
connect the power supply;
• open the e
vaporator casing;
•
remove the lamp protection grille;
•
remove the electrical box cover;
•
replace the lamp with one of the same power (see dataplate inside the evaporator casing);
• close the e
vaporator casing;
•
reconnect the power supply;
Replacing the uv lamp ballast
To replace the ballast, proceed as follows:
• dis
connect the power supply;
•
remove the control panel;
•
replace the ballast;
•
reconnect the power supply;