ERROR CODE
E5–E6
:
ROOM/CONDENSER SENSOR
FAILURE
The display on the user interface shows the ERROR codes. This condition
causes the following event:
¾
The Alarm Service Led is blinking
¾
The buzzer is active
¾
The display shows the ERROR code
“E5”
or
“E6”
ALARMS CONDITIONS
This type of error causes the following possible events:
¾
In any time chilling or freezing cycle works normally according to
the set-point values.
¾
In any time the defrosting cycles operates normally by time or by
temperature
¾
During any working cycle (chilling/freezing or maintenance cycles)
and if the room sensor become faulty (E5),
the door heating
element is active always.
SWICTH OFF ALARMS :
ONLY REPLACEMENT THE PROBE