ERROR CODE
E11
:
COMPRESSOR OVERLOAD
The compressor could be protected against overloads by thermistor
devices.
This type of Alarm is activated by the digital input J6 (7-8) on the main
board and it causes an interruption of the working cycle in progress.
Setting the parameter
“
CPt
”
on the unit is possible enable or disable this
digital inputs.
All functions could be restored automatically and a new cycle can re-
start again when the cause of the alarm is ended.
The display on the user interface shows the ERROR codes. This condition
causes the following event:
¾
The red Alarm Service Led is flashing
¾
The buzzer is active
¾
The display shows the ERROR code
“
E11
”
ALARMS CONDITIONS
High or Low temperature in the compressor due to at flash gas or air
flow compressor stopped
Or compressor windings faulty
- 74 -