Extraordinary maintenance
(120-180KG)
Replacing the power cable
To replace the power cable, proceed as follows:
• dis
connect the power supply;
•
remove the control panel;
•
replace the power cable;
•
reconnect the power supply.
Replacing the power cable for models arranged for remote unit
To replace the power cable, proceed as follows:
• dis
connect the power supply;
•
remove the electr
ical s
ystem box cover located on the
exter- nal r
oof of the applian
ce;
•
replace the power cable;
•
reconnect the power supply.
CAUTION
Use an H07RN-F power cable (code 60245IEC66) for the permanent connec
tion
t
o the mains;
in case of
replacement, use a type ha
ving
at least these character
istic
s. When r
eplacing the cabl
e, the
ear
th wi
r
e must be kept longer than the li
ve and neutr
al wi
res.