ERROR CODE
b1
:
HIGH CONDENSER TEMPERATURE
(NOT
PRESENT ON REMOTE UNIT)
The display on the user interface shows the ERROR codes. This
condition causes the following event:
¾
The Alarm Service Led is flashing
¾
The buzzer is active
¾
The display shows the ERROR code
“
b1
”
ALARMS CONDITIONS
This type of error occurs when the condensing temperature
reach a value higher than the parameter “
HTC
”
(HTC = condenser higher temperature alarm set).
CAUSES
¾
the condenser is dirty
¾
the condenser motor fan doesn’t run
¾
the probe condenser can be miscalibrated