EM-2115 APPENDIX A DESCRIPTION FRONT PANEL CONTROLS
(EM2115A-7)
will not reset or update the overload indicator circuit. For
more complete information, refer to Section II Paragraph
2.4.3 (Page 2-8).
c. RMS
The rms detector circuit produces a true rms measurement value of the de-
tected video signal. The charge and discharge times are a nominal 150 ms
with a 30 dB crest factor.
d. Average
The average detector circuit produces the true average value of the input
signal level. The chargeand discharge times are a nominal 150 ms with a
50 dB minimum crest factor.
e. Slideback
A rapid-decay peak detector circuit that, in conjunction with the Threshold
Control, provide a variable bias for aural or video extinction of peak level
signals.
e-1 Threshold Control
Type:
Cermet single turn, 280
rotation, 100 k
.
Function:
Used to adjust the aural or video extinction point for the Side-
back position.
A-7.1 Detector Indicators
Type:
LED.
Color:
Red.
Function:
To indicate the activated detector.
A-8.0 Amplitude Indication
The EM-2115 utilizes a dual metering system, with digital and analog meters, to indicate
the amplitude level of a detected signal.
A-8.1 Digital Meter
Type:
Three digit 1/2-inch LED display.
Color:
Red.
Function:
Indicates the input signal amplitude level in dB(µV). The meter circuit
automatically adds the attenuation setting of the receiver to the display indication.
Содержание EM-2115
Страница 1: ...INSTRUCTION MANUAL INTERFERENCE ANALYZER MODEL EM 2115 EMC 30...
Страница 68: ...EM 2115 3 0 PERFORMANCE CHECK EM2115S3 13...
Страница 104: ...EM 2115 4 0 SERVICE MAINTENANCE CALIBRATION EM2115S4 36...
Страница 106: ...EM 2115 4 0 SERVICE MAINTENANCE CALIBRATION EM2115S4 38...
Страница 108: ...EM 2115 4 0 SERVICE MAINTENANCE CALIBRATION EM2115S4 40...
Страница 110: ...EM 2115 4 0 SERVICE MAINTENANCE CALIBRATION EM2115S4 42...
Страница 112: ...EM 2115 4 0 SERVICE MAINTENANCE CALIBRATION EM2115S4 44...