Technical Data
A533-23-880 Issue C
2
Technical Data
Note:
Unless otherwise specified, data in the following sections applies to all models of iF system.
2.1
General
2.2
Performance
Dimensions
refer to Figures 10 and 11
Inlet and outlet
refer to Table 4
Warm-up time to nominal pumping performance
15 min
Minimum warm-up time to process gas pumping
4 hours
Vacuum system maximum leak-rate
1 x 10
-5
mbar l s
-1
(1 x 10
-3
Pa l s
-1
)
Exhaust system maximum leak-rate
1 x 10
-5
mbar l s
-1
(1 x 10
-3
Pa l s
-1
)
Ambient operating temperature range
5 to 40 °C
Maximum ambient operating humidity
90% RH
Noise level measured at 1 m from the pump
(with enclosure panels fitted)
refer to Table 4
Mass
refer to Table 4
Centre of mass/mass distribution
refer to Figure 12
Pumping speed range
refer to Figure 13
Peak pumping speed
refer to Table 4
Ultimate vacuum
refer to Table 4
Maximum inlet pressure
refer to Table 4
Maximum operating time at maximum inlet pressure
refer to Table 4
Table 4 - Technical Data
Parameter
50Hz
60Hz
Units
Typical peak pumping speed
1720
1800
m
3
h
-1
Typical ultimate vacuum with shaft seals purge only
(50 and 60 Hz)
8 x 10
-4
0.08
5 x 10
-4
0.05
mbar
Pa
Maximum inlet pressure (50 and 60 Hz)
Atmospheric
Atmospheric
Atmospheric
Atmospheric
mbar
Pa
Maximum operating time at maximum inlet pressure
(50 and 60 Hz)
60
60
Seconds
Inlet connection
ISO160
ISO160
-
Outlet connection
NW40
NW40
-
Mass
585
585
kg
Noise level
<64
<69
dB(A)