![Edwards iF1800 Скачать руководство пользователя страница 106](http://html1.mh-extra.com/html/edwards/if1800/if1800_instruction-manual_2366123106.webp)
A533-23-880 Issue C
Page 96
© Edwards Limited 2009. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
maintenance
Figure 48 - Removing/cleaning the iF exhaust system
6.8
Check the FDP pump oil-level
CAUTION
Do not check the oil-level when the iF system is operating. The correct oil-level may not be shown when the
pump is operating.
CAUTION
Ensure that the oil-level in the FDP pump is correct. If the pump oil-level is incorrect, pump performance may
be affected and the pump may be damaged.
You must check the oil-level every three months. An oil-level viewing port is provided on the right hand side panel
(viewed from the front of the system). These should be used as an indication only, for an accurate oil-level
assessment use the following procedure to check the oil-level.
WARNING
Do not remove the oil filler-plug while the pump is operating. If you do, hot oil may be ejected
from the pump.
WARNING
The majority of synthetic oils/greases can cause inflammation of the skin (dermatitis). Safety
precautions must be taken to prevent prolonged skin contact with these substances. Use of
suitable protective gloves and clothing along with respirator is recommended if contact with
substances is anticipated.
1. NW40 Blank
2. NW40 trapped O-ring
3. NW40 Clamps
4. Exhaust manifold
5. Silencer support bracket
6. Silencer
7. Check valve
8. Elbow