© Edwards Limited 2010. All rights reserved.
Page 43
Edwards and the Edwards logo are trademarks of Edwards Limited.
Maintenance
D397-50-880 Issue C
Software
Module
No.
Parameter
Units
Default value
904
Master gauge
Numbered
options
0 ( = None)
904
Master gauge units
Numbered
options
59 ( = Pascals)
904
ON Setpoint
IEEE-754 format 0x40200000 ( = 2.5E-4 pascals)
904
OFF setpoint
IEEE-754 format 0x41200000 ( = 1.0E-3 pascals)
904
Control from gauge
selected.
Numbered
options
0 ( = disabled)
904
Start delay
Minutes
0
905
Max ramp time to 50%
speed.
Minutes
8
905
Max droop time below 50%
speed
Minutes
8
913
Master object
Numbered
options
0 ( = None)
913
Master object units
Numbered
options
59 ( = Pascals)
913
ON Setpoint
IEEE-754 format 0x40200000 ( = 2.5E-4 pascals)
913
OFF setpoint
IEEE-754 format 0x41200000 ( = 1.0E-3 pascals)
913
Control from object
selected.
Numbered
options
0 ( = disabled)
913
Gas type
Numbered
options
0 ( = Nitrogen)
913
Filter
Numbered
options
0 ( = Filter off)
913
ASG range
Numbered
options
0 ( = 1000 mbar)
914
Master object
Numbered
options
0 ( = None)
914
Master object units
Numbered
options
59 ( = Pascals)
Содержание D397-50-000
Страница 67: ...This page has been intentionally left blank ...
Страница 68: ...This page has been intentionally left blank ...
Страница 71: ...This page has been intentionally left blank ...
Страница 73: ...This page has been intentionally left blank ...
Страница 74: ...This page has been intentionally left blank ...
Страница 76: ...P800 80 000 Issue T edwardsvacuum com ...