Faceplate Timer, Features/Options
21
Advanced/Service Menu, continued
Set Backwash Time:
Follow directions described before to get to Ad-
vanced/Service Menu. Move cursor to Set Backwash Time and press
SELECT/EXIT (
¿
) to enter this screen. Time can be changed from
1 to 30 minutes. See chart on page xx for recommended backwash
time. Press SELECT/EXIT (
¿
) to exit to the Primary Menu.
Set 2nd Backwash:
Follow directions described before to get to Ad-
vanced/Service Menu. Move cursor to Set 2nd Backwash and press
SELECT/EXIT (
¿
) to enter this screen. Default is Off. Use the (
-
)
button to set to On. When set to On, unit will always perform a 2nd
backwash. Press SELECT/EXIT (
¿
) to exit to the Primary Menu.
Set Fast Rinse:
Follow directions described before to get to Ad-
vanced/Service Menu. Move cursor to Set Fast Rinse and press SE-
LECT/EXIT (
¿
) to enter this screen. Time can be changed from 1
to 30 minutes. Press SELECT/EXIT (
¿
) to exit to the Primary Menu.
Set Model:
Follow directions described before to get to Advanced/
Service Menu. Move cursor to Set Model and press SELECT/EXIT
(
¿
) to enter this screen. Warning screen will display, press (
-
) to con-
tinue. Use the (
-
) or (
¯
) buttons to change to new model code. NOTE:
If this feature is changed, it will delete all information stored in the tim-
er (Hardness, Recharge time will have to be reset. All usage history
will be cleared). Press SELECT/EXIT (
¿
) to exit to the Primary Menu.
Restore To Factory Settings:
Follow directions described before to
get to Advanced/Service Menu. Move cursor to Restore System and
press SELECT/EXIT (
¿
) to enter this screen. Default is No. If set
to Yes will restore timer to factory settings. NOTE: This will affect ALL
settings, and timer will go through first time set--up screens again.
Press SELECT/EXIT (
¿
) to exit to the Primary Menu.