7.9.4
Access code
CAUTION!
In order to exclude the possibility of the pump being used improperly and / or of
the system parameters being adjusted inadvertently, the pump software can
and should be protected by the integrated multi-stage
[Access code]
.
The safety setting is not activated when the pump is first started!
When the first configuration of the pump is performed, we strongly
recommend enabling the [Access code] ‘Administrator (A)’ and
‘Operator (O)’ and providing the [Access code] only to the authorised
personnel!
User with the
[Access code]
‘Operator (O)’
have fewer authorisations in the setting
options. The
[Access code]
for
‘Administrator (A)’
has complete access to all the functions
of
‘EcoAdd’
pump enabled for the user.
–
In the [Configuration] first the entry of the [access codes] of ‘Administrator
(A)’ levels is done, and then the entry of ‘Operator (O)’ Level 1
–
If the [Access code] of ‘Administrator (A)’ is not set, then the setting of
[Access code] of ‘Operator (O)’ is not displayed.
Thus the pump does not have any protection against access!
–
After setting the [Access code] of ‘Administrator (A)’ the [Access code] of
‘Operator (O)’ can be set or also omitted.
–
If no [Access code] of ‘Operator (O)’ is specified, then for each setting the
[Access code] of ‘Administrator (A)’ is required.
–
If both [access codes] are present, there is a reduction in the authorisations
by querying the [Access code] of ‘Operator (O)’ .
–
When using only one [access code], general unrestricted access
( ‘Administrator (A)’ ) is guaranteed!
Overview of access authorisations!
= Operator, = Administrator
Restrictions for users with [Access code] ‘Operator (O)’ :
n
Changing the
[Access code]
is not possible.
n
Changing the
[Metering mode]
is not possible.
n
Changing the
[Operating Mode]
is not possible.
n
Changing the
[Configuration]
is not possible.
n
Ex and import parameters via USB is not possible.
n
No authorisation to change the metering capacity.
n
No authorisation to change the concentration.
n
No authorisation to change the metering capacity per
pulse.
n
No authorisation to carry out pump servicing.
Control / software
88
Rev. 2-05.2018