7.8.3
[Operating mode] [Power]
In the
‘Power’
operating mode the metering capacity of the pump is determined by the
level of the incoming standardised current signal (0/4-20 mA).
Example:
Input signal 4 - 20 mA = metering capacity 0 - 100%
Terminal assignment:
Fig. 38: Terminal assignment: ‘Power’
The following should be noted here:
–
Approx. load 50 Ohm.
–
Input not voltage-free.
–
Note the polarity of the connected signal!
Control / software
77