417102214_EDPL_V60.docx
103
Rev. 1.12.11
10.5.4.1 Calibration data table
The pump capacity in l/h is allocated to the pump’s electronics on the basis of the calibration
values entered in the table.
Example:
specified value of 3.67 l results in a pump capacity of 220 l/h.
NOTE
These values relate to the metering medium, i.e. water, at 20°C.
ED
PL
V6
0
Pump
Pump capacity [l/h]
Pump calibration value [l]
Fig. 10.56
220
3,67
480
8,0
670
11,17
10.6
Operating data
Open main menu as descripted at chapter
operating data
by using the
key.
Acknowledge your choice with the Start/Stop key. If you push the
and
keys at once
(Function: „Menü Exit“) you get back to operating mode.
The following operating data is recorded and displayed under this menu item:
•
Hours in operation, Litres, Number of pulses
NOTE
The values in "Operating data" are updated anew every time the "Operating data" menu
option is called up. This means that if the operating data is called up while the pump is
running, the incrementing of the values is not displayed.
10.6.1 Overview
Fig. 10.57
see chapter
see chapter
see chapter
Содержание 417102214
Страница 60: ...417102214_EDPL_V60 docx 60 Rev 1 12 11 14 7 3 F rderleistung Typ 06700 0 4 MPa 4 bar Abb 14 5...
Страница 61: ...417102214_EDPL_V60 docx 61 Rev 1 12 11 15 Konformit tserkl rung...
Страница 120: ...417102214_EDPL_V60 docx 120 Rev 1 12 11 14 7 3 Pump capacity on type 06700 0 4 MPa 4 bar Fig 14 5...
Страница 121: ...417102214_EDPL_V60 docx 121 Rev 1 12 11 15 Declaration of conformity...
Страница 180: ...417102214_EDPL_V60 docx 180 Rev 1 12 11 14 7 3 D bit type 06700 0 4 MPa 4 bar Fig 14 5...
Страница 181: ...417102214_EDPL_V60 docx 181 Rev 1 12 11 15 D claration de conformit...