10.2
Metering mode
The "Metering mode" menu option can be used to adapt the maximum metering capacity of
the pump and thus the suction duration per stroke (suction stroke duration) to high product
viscosities or difficult suction conditions.
IMPORTANT
The pump must be re-calibrated when switching between individual metering modes!
Therefore, the icon "c!" appears in the operating level display.
Once automatic calibration has been correctly performed, the icon "
" then appears!
The following settings are possible:
Metering
mode
Display
Max. stroke frequency/
(max. metering cap.)
*
(at a 100 % setting)
Suction stroke
duration
Min. metering
stroke duration
(at a 100 % setting)
Total stroke
duration
(C metering stroke)
Standard [s]
120 /min
(220 l/h)*
200 ms
300 ms
500 ms
medium [m]
100 /min
(183 l/h)*
250 ms
350 ms
600 ms
low [l]
80 /min
(147 l/h)*
350 ms
400 ms
750 ms
variable [v]
derived from the settings for
suction stroke or metering
stroke duration
variable from 200
to 400 ms
variable from 300
to 450 ms
between 500 ms and
950 ms, depending
on the setting
*
displayed value depending on the pump size and calibration
NOTE
The details about the suction stroke and metering stroke times are theoretical values.
They may vary according to suction line lengths, back-pressure, etc.
10.2.1 Selection
Open main menu as descripted at chapter
metering mode
by using the
key. Acknowledge your choice with the Start/Stop key. If you push the
and
keys at
once (Function: „Menü Exit“) you get back to operating mode.
Fig. 10.3
The maximum stroke frequency [1/min] and the
maximum metering capacity [l/h] are displayed
along the bottom in the respective metering
mode. The value for the maximum metering
capacity [l/h] is dependent on the pump size
and calibration.
10.2.1.1 Variable metering mode selection / setting
Fig. 10.4
Содержание 417102214
Страница 60: ...417102214_EDPL_V60 docx 60 Rev 1 12 11 14 7 3 F rderleistung Typ 06700 0 4 MPa 4 bar Abb 14 5...
Страница 61: ...417102214_EDPL_V60 docx 61 Rev 1 12 11 15 Konformit tserkl rung...
Страница 120: ...417102214_EDPL_V60 docx 120 Rev 1 12 11 14 7 3 Pump capacity on type 06700 0 4 MPa 4 bar Fig 14 5...
Страница 121: ...417102214_EDPL_V60 docx 121 Rev 1 12 11 15 Declaration of conformity...
Страница 180: ...417102214_EDPL_V60 docx 180 Rev 1 12 11 14 7 3 D bit type 06700 0 4 MPa 4 bar Fig 14 5...
Страница 181: ...417102214_EDPL_V60 docx 181 Rev 1 12 11 15 D claration de conformit...