11.1.4.3 Installation
Fig. 11.6
Clean the splined shaft (pos.
3
) and housing flange (pos.
4
).
Coat the motor shaft (pos.
2
) and splined shaft (pos.
3
) with Teflon
grease.
Place the motor shaft (pos.
2
) right onto splined shaft (Pos.
3
) and
press softly until the flange is reached. Do not set the motor on its
edge.
Turn the motor in a way that the frequency convertor points
forward, in the direction of the front panel. (see Fig. 11.5).
Place on washers and fastening nuts (Fig 11.5, pos.
7
) and tighten
them crosswise (tightening torque of 12 Nm).
Guide the motor control line (Fig. 11.5, pos.
5
) through the cable
screw fitting (Fig. 11.5, pos.
6
)
Fig. 11.7
connect all the wires to the motor control line connector (Fig. 11.5, pos.
21
)
following the colour coding (see Fig. 11.7).
Attach the motor control line connector on the mainboard (Fig. 11.5, pos.
12
).
Insert the mainboard (Fig. 11.5, pos.
16
) and reattach the front panel
(Fig. 11.5, pos.
19
).
Insert the front fastening screws (Fig. 11.5, pos.
20
) on the top (short) and bottom (long) and
tighten them crosswise (torque of 3 Nm).
Attach the mains lead (Fig. 11.5, pos.
1
).
CAUTION
Tighten the motor fastening nuts after 24 hours in operation. (torque of 12 Nm)!
11.1.5 Replacement of the front panel
Unplug the mains lead
(Fig. 11.5, pos.
1
)
.
Loosen the front fastening screws
(Fig. 11.5,
pos.
20
) at the top (short) & bottom (long).
(There is no need to loosen the fastening screws in the middle on the front).
Remove operating front panel (
Fig. 11.5,
pos.
19
) with mainboard (
Fig. 11.5,
pos.
16
).
Unplug the connector for the front panel/connection line
(Fig. 11.5,
pos.
13
) from the
mainboard.
Disconnect the on/off switch connection line connector X4
(Fig. 11.5,
pos.
17
) from the
board.
Unplug connector X1
(Fig. 11.5,
pos.
15
) and disconnect connection wires leading to the
level input socket (terminals 1,2,3) (take note of the sequence of colours!)
If other control inputs are wired to connectors X1, X2 or X3 (see chapter
Mains
supply connection
”for an overview of terminals), unplug the connectors and disconnect
all the wires (take note of the sequences of terminals!)
Where necessary, loosen the cable screw fittings on the front panel and remove the
control cables.
Take hold of the front panel and, if necessary, insert appropriate cable screw fittings.
If there are any control lines present, guide them through the appropriate cable screw
fittings, tighten the screw fittings and connect the lines to the appropriate terminals.
Re-establish all plug-in connections.
Insert the mainboard
(Fig. 11.5,
pos.
16
) and reattach the front panel (
Fig. 11.5,
pos.
19
).
Insert the fastening screws
(Fig. 11.5,
pos.
20
) on the top and bottom and tighten them
crosswise (torque of 3 Nm).
Re-establish mains voltage supply
(Fig. 11.5,
pos.
1
).
11.1.6 Replacement of boards
, however, also unplug the connector for the motor control
line (pos.
4
) and connector for the rotary transducer sensor line (pos.
5
) and re-attach
them to the new board.
Содержание 417102214
Страница 60: ...417102214_EDPL_V60 docx 60 Rev 1 12 11 14 7 3 F rderleistung Typ 06700 0 4 MPa 4 bar Abb 14 5...
Страница 61: ...417102214_EDPL_V60 docx 61 Rev 1 12 11 15 Konformit tserkl rung...
Страница 120: ...417102214_EDPL_V60 docx 120 Rev 1 12 11 14 7 3 Pump capacity on type 06700 0 4 MPa 4 bar Fig 14 5...
Страница 121: ...417102214_EDPL_V60 docx 121 Rev 1 12 11 15 Declaration of conformity...
Страница 180: ...417102214_EDPL_V60 docx 180 Rev 1 12 11 14 7 3 D bit type 06700 0 4 MPa 4 bar Fig 14 5...
Страница 181: ...417102214_EDPL_V60 docx 181 Rev 1 12 11 15 D claration de conformit...