417102214_EDPL_V60.docx
87
Rev. 1.12.11
10.3.2.2 Display value in the operating level / Setting
The metering quantity can be configured/adjusted in the operating level during operations.
NOTE
The original value is retained if the newly set value is not confirmed within 10 seconds by
pressing the START/STOP button.
Strokes/min
Per cent (%)
Fig. 10.7
Fig. 10.8
Litres
Gallons
Fig. 10.9
Fig. 10.10
10.3.3 Operating mode / Pulse
In "Pulse" operating mode, the pump meters a defined quantity in proportion to an incoming
pulse rate (for example, from a contact water meter). The pulse interval (ml, l / pulse) for the
flow meter being used must be entered here first of all.
The required concentration in % or the metering quantity per pulse [ml/p] can then be
selected in the operating level.
The pump software independently calculates the necessary metering stroke speed or
metering quantity from these parameters and sets the pump accordingly.
10.3.3.1 Selection
Fig. 10.11
Setting range:
10 ml – 100 l / pulse